No increase of the blood oxygenation level-dependent functional magnetic resonance imaging signal with higher field strength: implications for brain activation studies.

Jörg U Seehafer1, Daniel Kalthoff, Tracy D Farr, Dirk Wiedermann, Mathias Hoehn.   

Abstract

Experimental data up to 7.0 T show that the blood oxygenation level-dependent (BOLD) signal of functional magnetic resonance imaging (fMRI) increases with higher magnetic field strength. Although several studies at 11.7 T report higher BOLD signal compared with studies at 7.0 T, no direct comparison at these two field strengths has been performed under the exact same conditions. It therefore remains unclear whether the expected increase of BOLD effect with field strength will still continue to hold for fields >7.0 T. To examine this issue, we compared the BOLD activation signal at 7.0 and 11.7 T with the two common sequences, spin-echo (SE) and gradient-echo (GE) echo planar imaging (EPI). We chose the physiologically well controlled rat model of electrical forepaw stimulation under medetomidine sedation. While a linear to superlinear increase in activation with field strengths up to 7.0 T was reported in the literature, we observed no significant activation difference between 7.0 and 11.7 T with either SE or GE. Discussing the results in light of the four-component model of the BOLD signal, we showed that at high field only two extravascular contributions remain relevant, while both intravascular components vanish. Constancy of the BOLD effect is discussed due to motional narrowing, i.e., susceptibility gradients become so strong that phase variance of diffusing spins decreases and therefore the BOLD signal also decreases. This finding will be of high significance for the planning of future human and animal fMRI studies at high fields and their quantitative analysis.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20392946      PMCID: PMC6632745          DOI: 10.1523/JNEUROSCI.0844-10.2010

Source DB:  PubMed          Journal:  J Neurosci        ISSN: 0270-6474            Impact factor:   6.167


  10 in total

Review 1.  The future of ultra-high field MRI and fMRI for study of the human brain.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-28       Impact factor: 6.556

2.  Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.

Authors:  Paula Ramos Delgado; Ekkehard Küstermann; André Kühne; Jason M Millward; Thoralf Niendorf; Andreas Pohlmann; Martin Meier
Journal:  Methods Mol Biol       Date:  2021

3.  Direct imaging of macrovascular and microvascular contributions to BOLD fMRI in layers IV-V of the rat whisker-barrel cortex.

Authors:  Xin Yu; Daniel Glen; Shumin Wang; Stephen Dodd; Yoshiyuki Hirano; Ziad Saad; Richard Reynolds; Afonso C Silva; Alan P Koretsky
Journal:  Neuroimage       Date:  2011-08-07       Impact factor: 6.556

4.  Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging.

Authors:  Xiaolei Song; Jiadi Xu; Shuli Xia; Nirbhay N Yadav; Bachchu Lal; John Laterra; Jeff W M Bulte; Peter C M van Zijl; Michael T McMahon
Journal:  Magn Reson Med       Date:  2014-12-16       Impact factor: 4.668

5.  Improving the use of principal component analysis to reduce physiological noise and motion artifacts to increase the sensitivity of task-based fMRI.

Authors:  David A Soltysik; David Thomasson; Sunder Rajan; Nadia Biassou
Journal:  J Neurosci Methods       Date:  2014-12-04       Impact factor: 2.390

6.  Effects of the α₂-adrenergic receptor agonist dexmedetomidine on neural, vascular and BOLD fMRI responses in the somatosensory cortex.

Authors:  Mitsuhiro Fukuda; Alberto L Vazquez; Xiaopeng Zong; Seong-Gi Kim
Journal:  Eur J Neurosci       Date:  2012-10-29       Impact factor: 3.386

7.  Technical and conceptual considerations for performing and interpreting functional MRI studies in awake rats.

Authors:  Marcelo Febo
Journal:  Front Psychiatry       Date:  2011-07-12       Impact factor: 4.157

Review 8.  Innovative Perspective: Gadolinium-Free Magnetic Resonance Imaging in Long-Term Follow-Up after Kidney Transplantation.

Authors:  Mick J M van Eijs; Arjan D van Zuilen; Anneloes de Boer; Martijn Froeling; Tri Q Nguyen; Jaap A Joles; Tim Leiner; Marianne C Verhaar
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

9.  The current status and trend of the functional magnetic resonance combined with stimulation in animals.

Authors:  Jiayang Huang; Yusi Zhang; Qi Zhang; Linxuan Wei; Xiwen Zhang; Caiping Jin; Junchao Yang; Zuanfang Li; Shengxiang Liang
Journal:  Front Neurosci       Date:  2022-09-23       Impact factor: 5.152

10.  Gradient-echo and spin-echo blood oxygenation level-dependent functional MRI at ultrahigh fields of 9.4 and 15.2 Tesla.

Authors:  SoHyun Han; Jeong Pyo Son; HyungJoon Cho; Jang-Yeon Park; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2018-09-05       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.