Literature DB >> 20392629

Ultrasensitive electrochemiluminescence immunosensor based on luminol functionalized gold nanoparticle labeling.

Dayong Tian1, Chunfeng Duan, Wei Wang, Hua Cui.   

Abstract

An ultrasensitive electrochemiluminescence (ECL) immunosensor based on luminol functionalized gold nanoparticle (AuNP) labeling was developed using human immunoglobulin G (hIgG) as a model analyte. The primary antibody biotin-conjugated goat-anti-human IgG was first immobilized on a streptavidin coated AuNP modified electrode, then the antigen (human IgG) and the luminol functionalized AuNP-labeled second antibody were conjugated successively to form a sandwich-type immunocomplex, i.e. immunosensor. ECL was carried out with a double-step potential in carbonate buffer solution containing 1.0 mmol/L H(2)O(2). Since thousand of luminol molecules were coated on the surface of AuNPs to realize labeling of multiple molecules with CL activity at a single antibody and the amplification of AuNPs and biotin-streptavidin system was utilized, luminol ECL signal could be enhanced greatly, finally resulting in extremely high sensitivity. The ECL method shows a detection limit of 1.0 pg/mL (S/N=3) for hIgG, which is superior to all previously reported methods for the determination of hIgG. Moreover, the proposed method is also simple, stable, specific, and time-saving, avoiding the complicated stripping procedure during CL detection and the uncontrollable synthesis of irregular nanoparticles compared with other chemiluminescence immunoassay based on AuNP labeling. Additionally, the labeling procedure is also superior to that of other reported multilabeling strategies, such as Ru complex-encapsulated polymer microspheres, and most of Ru complex-encapsulated liposomes in simplicity, stability, labeling property and practical applicability. Finally, the proposed method has been successfully applied to the detection of hIgG in human serums. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20392629     DOI: 10.1016/j.bios.2010.03.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

2.  Dual-Readout Sandwich Immunoassay for Device-Free and Highly Sensitive Anthrax Biomarker Detection.

Authors:  Isaac N Larkin; Viswanadham Garimella; Gokay Yamankurt; Alexander W Scott; Hang Xing; Chad A Mirkin
Journal:  Anal Chem       Date:  2020-05-21       Impact factor: 6.986

Review 3.  Prospects of nanotechnology in clinical immunodiagnostics.

Authors:  Anees A Ansari; Mansour Alhoshan; Mohamad S Alsalhi; Abdullah S Aldwayyan
Journal:  Sensors (Basel)       Date:  2010-07-07       Impact factor: 3.576

Review 4.  Noble metal nanoparticles for biosensing applications.

Authors:  Gonçalo Doria; João Conde; Bruno Veigas; Leticia Giestas; Carina Almeida; Maria Assunção; João Rosa; Pedro V Baptista
Journal:  Sensors (Basel)       Date:  2012-02-07       Impact factor: 3.576

5.  Metal-linked Immunosorbent Assay (MeLISA): the Enzyme-Free Alternative to ELISA for Biomarker Detection in Serum.

Authors:  Ru-Jia Yu; Wei Ma; Xiao-Yuan Liu; Hong-Ying Jin; Huan-Xing Han; Hong-Yang Wang; He Tian; Yi-Tao Long
Journal:  Theranostics       Date:  2016-06-27       Impact factor: 11.556