Abstract
This study evaluated the effectiveness of Fenton's technique for the treatment of semi-aerobic landfill leachate collected from Pulau Burung Landfill Site (PBLS), Penang, Malaysia. The Fe2+ or Fe3+ as catalyst and H2O2 as oxidizing agent are commonly used for the classical Fenton's reaction. In present study, the effect of operating conditions such as pH, reaction time, molar ratio, agitation rate, feeding mode and Fenton reagent concentrations which are important parameters that affect the removal efficiencies of Fenton method were investigated. Under the most favorable conditions, the highest removals of 58.1 and 78.3% were observed for COD and color, respectively. In general, the best operating conditions were pH = 3, Fe = 560 mg L(-1), H2O2 = 1020 mg L(-1), H2O2/Fe2+ molar ratio = 3, agitation rate = 400 rpm and reaction time = 120 minutes. The results highlighted that stepwise addition of Fenton's reagent was more effective than adding the entire volume in a single step. Excessive hydrogen peroxide and iron have shown scavenging effects on hydroxyl radicals and reduced degradation of refractory organics in the landfill leachate.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20390917 DOI: 10.1080/10934521003648883
Source DB: PubMed Journal: J Environ Sci Health A Tox Hazard Subst Environ Eng ISSN: 1093-4529 Impact factor: 2.269