Literature DB >> 2038976

Japanese NiTi coils used to move molars distally.

A A Gianelly1, J Bednar, V S Dietz.   

Abstract

Japanese NiTi superelastic coils, exerting 100 gm of force, were compressed against the maxillary first molars and moved the molars distally 1 to 1.5 mm/month. Anchorage was obtained with a modified Nance appliance cemented onto the first premolars in conjunction with a fixed appliance.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2038976     DOI: 10.1016/S0889-5406(05)81633-6

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  12 in total

1.  Class II correction with magnets and superelastic coils followed by straight-wire mechanotherapy. Occlusal changes during and after dental therapy.

Authors:  L Bondemark; J Kurol
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

2.  [Cervical headgear with angled outer arms. A biomechanically comprehensible system?].

Authors:  M Breier; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1995-05

3.  [Headgear-free molar distalization].

Authors:  C Manhartsberger
Journal:  Fortschr Kieferorthop       Date:  1994-12

4.  Sagittal, rotational and transverse changes with three intraoral distalization force systems: Jones jig, distal jet and first class.

Authors:  Silvio-Augusto Bellini-Pereira; Aron Aliaga-Del Castillo; Lorena Vilanova; Mayara-Paim Patel; Rachelle-Simões Reis; Roberto-Henrique-da Costa Grec; José-Fernando-Castanha Henriques; Guilherme Janson
Journal:  J Clin Exp Dent       Date:  2021-05-01

5.  Fabrication and evaluation of a noncompliant molar distalizing appliance: bonded molar distalizer.

Authors:  A Sodagar; M S Ahmad Akhoundi; A Rafighii; S Arab
Journal:  J Dent (Tehran)       Date:  2011-09-30

6.  Use of the intraosseous screw for unilateral upper molar distalization and found well balanced occlusion.

Authors:  Ibrahim Erhan Gelgor; Ali Ihya Karaman; Tamer Buyukyilmaz
Journal:  Head Face Med       Date:  2006-11-09       Impact factor: 2.151

7.  Comparative evaluation of molar distalization therapy with erupted second molar: Segmented versus Quad Pendulum appliance.

Authors:  Alberto Caprioglio; Mauro Cozzani; Mattia Fontana
Journal:  Prog Orthod       Date:  2014-08-06       Impact factor: 2.750

8.  Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial.

Authors:  Ahmad Sharafeddin Burhan
Journal:  Korean J Orthod       Date:  2013-04-25       Impact factor: 1.372

9.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08

10.  Maxillary molar distalization with aligners in adult patients: a multicenter retrospective study.

Authors:  Serena Ravera; Tommaso Castroflorio; Francesco Garino; Sam Daher; Giovanni Cugliari; Andrea Deregibus
Journal:  Prog Orthod       Date:  2016-04-18       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.