Evgeny V Shashkov1, Ekaterina I Galanzha, Vladimir P Zharov.
Abstract
An integrated Raman-based cytometry was developed with photothermal (PT) and photoacoustic (PA) detection of Raman-induced thermal and acoustic signals in biological samples with Raman-active vibrational modes. The two-frequency, spatially and temporally overlapping pump-Stokes excitation in counterpropagating geometry was provided by a nanosecond tunable (420-2300 nm) optical parametric oscillator and a Raman shifter (639 nm) pumped by a double-pulsed Q-switched Nd:YAG laser using microscopic and fiberoptic delivery of laser radiation. The PA and PT Raman detection and imaging technique was tested in vitro with benzene,Entities:
Mesh:
Substances:
Year: 2010 PMID: 20389713 PMCID: PMC3404859 DOI: 10.1364/OE.18.006929
Source DB: PubMed Journal: Opt Express ISSN: 1094-4087 Impact factor: 3.894
Fig. 1Method of PA and PT Raman cytometry with two-frequency excitation of the vibrational mode of the cells. (a) Level scheme of the Raman transition. (b) Schematic of cell irradiation. (c) Microscopic and fiber-based optical diagram. T, telescope; D, diaphragm; A, attenuator. (d) Double pumping of two-channel Nd:YAG laser. (e) Scheme details.
Fig. 2PA Raman signals in liquids obtained with parallel polarization of the pump and Stokes beams. (a) PA Raman spectra (PARS) of acetone obtained in a thin (120 μm) microscope slide by scanning of first beam in the visible spectral range (PARSVIS) and in the NIR range (PARSNIR) at a fixed second beam wavelength of 639 nm (15,649 cm−1). Dash curves show linear PA background during spectral scanning of first beam alone (i.e., without second beam at 639 nm). (b) PA Raman spectra of benzene obtained in a microscope slide at a fixed pump wavelength of 639 nm and spectral scanning of a Stokes beam in the NIR range. (c) PA signal amplitude as a function of delay time between the pump and Stokes beams for acetone. (d) PA Raman signal for acetone at delays of 0 (top, left) and 20 ns (top, right), compared to signals induced by the pump (bottom, left) and the Stokes (bottom, right) beams alone. Amplitude and time scale: 10 mV/div and 1 μs/div.
Fig. 3PA Raman signals in olive droplets in a cuvette. (a) PARS at pump and Stokes beam frequencies in the visible and NIR ranges obtained by scanning at a pump beam wavelength tuned in the visible range and at a fixed Stokes wavelength and by scanning at a fixed pump beam wavelength and at a Stokes beam wavelength in the NIR range. (b) PA Raman signal amplitude as a function of the pump laser energy at 529 nm. (c,d) PA signal amplitude as function of delay time between pump and Stokes pulses with pump wavelengths in the visible (c) and the NIR ranges (d). (e) PT Raman signal at a νP of 539 nm and a νS of 639 nm at delays of 0 (left) and 20 ns (right). (f) Linear PA signals at delays of 2.5 μs (left), as well as with a 1-mm distance between pump and Stokes beams (right). Amplitude and time scales: 50 mV/div and 1 μs/div.
Fig. 4Linear and nonlinear PA/PT effects in CNTs. (a) PA signal as a function of laser energy. The insets show conventional (i.e., with one-frequency laser excitation) PT signals in linear (left) and nonlinear (right) modes associated with microbubble formation around overheated CNT clusters. (b) PA Raman signal amplitude as function delay between pump and Stokes beams. The inset shows PA signal at delays of 0 (left) and 30 ns (right). (c) PA Raman spectra at delays of 0 and 30 ns between the pump and Stokes beams.
Fig. 5Linear and nonlinear PA effects in chylomicron phantoms and cells in vitro. (a) PA signal in breast cancer at delays of 0 (left) and 20 ns (right). (b,c) PA signals in 200-nm chylomicron phantoms at delays of 0 (left) and 20 ns (right) in the visible (b) and the NIR (c) spectral ranges.
Fig. 6PA/PT detection of adipocytes in vivo in a mouse mesentery model. (a) Mouse mesentery with single layer of adipocytes and the He-Ne probe beam. (b) PT Raman image of a single adipocyte in vivo using two wavelengths: 835 nm as pump (30 µJ) and 639 nm (25 µJ) as Stokes wave. (c) Conventional PT image of a single adipocyte in vivo using a 550 nm (50 µJ) for heating of cellular cytochromes, and 639 nm, as probe beam (10 nJ) at 30-ns delay [26]. (d) PA Raman signals from adipocytes in vitro at delays of 0 (left) and 20 ns (ritgh). (e) PA Raman signals from adipocytes in vivo at delays of 0 (left) and 20 ns (right). The signal oscillations are associated with reflections of acoustic waves in the cuvette. The time scales: 1μs/div (d), and 10 μs/div (e).