Abstract

OBJECTIVE: To examine the suitability of commonly available ballpoint pens as a substitute emergency tracheostomy tube.
METHODS: Commonly available ballpoint pens were examined and compared against two standard cricothyroidotomy sets. The pens were evaluated for dimensions, speed of construction of a temporary tracheostomy tube and airway resistance with differing flow rates.
RESULTS: Internal diameters of the pens varied considerably. Time taken to construct a temporary tube ranged from 3 to 170 s, and in the majority of pens the airway resistance increased dramatically as the airflow rate increased.
CONCLUSION: Contrary to popular belief, the majority of ballpoint pens appear unsuitable for use as a substitute tracheostomy tube. In this study only two pens fulfilled the criteria for use: the Baron retractable ballpoint and the BIC soft feel Jumbo.

Entities:  

Mesh:

Year:  2010        PMID: 20385693     DOI: 10.1136/emj.2008.069294

Source DB:  PubMed          Journal:  Emerg Med J        ISSN: 1472-0205            Impact factor:   2.740


  1 in total

1.  [Comparison of ready-to-use devices for emergency cricothyrotomy : randomized and controlled feasibility study on a mannequin].

Authors:  V Helmstaedter; W A Wetsch; B W Böttiger; J Hinkelbein
Journal:  Anaesthesist       Date:  2012-04-21       Impact factor: 1.041