PURPOSE: To evaluate the stability of visual performance after implantation of a diffractive aspheric silicone multifocal intraocular lens (MIOL). METHODS: Thirty eyes of 15 patients received the Tecnis MIOL ZM900 (Abbot Medical Optics) after cataract extraction at Tokyo Dental College Suidobashi Hospital. The uncorrected and best-corrected distance visual acuities (UCDVA, BCDVA); uncorrected, distance-corrected and best-corrected near VAs (UCNVA, DCNVA and BCNVA); spherical equivalent refraction, spectacle independence, contrast sensitivity and posterior capsule opacification (PCO) were measured at 1 week; 1, 3 and 6 months; and 1 and 2 years postoperatively. RESULTS: Two years postoperatively, the UCDVA was 0.01 logMAR, BCDVA -0.09 logMAR, UCNVA 0.19 logMAR, DCNVA 0.1 logMAR and BCNVA 0.04 logMAR. There was no significant change from 1 week through 2 years. The percent of spherical equivalent refraction error within ± 0.5 diopter was 63.4% at 2 years. No patient required spectacles for reading; two patients have used spectacles for intermediate vision when necessary. One eye underwent Nd:YAG laser posterior capsulotomy because of PCO. CONCLUSION: The visual performance after implantation of the Tecnis MIOL was stable for 2 years. A low rate of PCO contributed to the long-term visual performance.
PURPOSE: To evaluate the stability of visual performance after implantation of a diffractive aspheric silicone multifocal intraocular lens (MIOL). METHODS: Thirty eyes of 15 patients received the Tecnis MIOL ZM900 (Abbot Medical Optics) after cataract extraction at Tokyo Dental College Suidobashi Hospital. The uncorrected and best-corrected distance visual acuities (UCDVA, BCDVA); uncorrected, distance-corrected and best-corrected near VAs (UCNVA, DCNVA and BCNVA); spherical equivalent refraction, spectacle independence, contrast sensitivity and posterior capsule opacification (PCO) were measured at 1 week; 1, 3 and 6 months; and 1 and 2 years postoperatively. RESULTS: Two years postoperatively, the UCDVA was 0.01 logMAR, BCDVA -0.09 logMAR, UCNVA 0.19 logMAR, DCNVA 0.1 logMAR and BCNVA 0.04 logMAR. There was no significant change from 1 week through 2 years. The percent of spherical equivalent refraction error within ± 0.5 diopter was 63.4% at 2 years. No patient required spectacles for reading; two patients have used spectacles for intermediate vision when necessary. One eye underwent Nd:YAG laser posterior capsulotomy because of PCO. CONCLUSION: The visual performance after implantation of the Tecnis MIOL was stable for 2 years. A low rate of PCO contributed to the long-term visual performance.
Authors: Mike P Holzer; Rudy M M A Nuijts; Soraya M R Jonker; Erik L J G Mertens; Asim Bozkurt Sener; Jorge A O Cazal; Antoni Salvador Playa; Ramon Ruiz Mesa; Bettina C Thomas Journal: Clin Ophthalmol Date: 2021-05-21