Literature DB >> 20384299

Electrochemistry in diabetes management.

Adam Heller1, Ben Feldman.   

Abstract

Diabetes devastates lives and burdens society. Hypoglycemic (low glucose) episodes cause blackouts, and severe ones are life-threatening. Periods of hyperglycemia (high glucose) cause circulatory disease, stroke, amputations, blindness, kidney failure and nerve degeneration. In this Account, we describe the founding of TheraSense, now a major part of Abbott Diabetes Care, and the development of two products that have improved the lives of people with diabetes. The first, a virtually painless microcoulometer (300 nL volume), the FreeStyle blood glucose monitoring system, was approved by the FDA and became available in 2000. In 2009, this system was used in more than one billion blood assays. The second, the enzyme-wiring based, subcutaneously-implanted FreeStyle Navigator continuous glucose monitoring system, was approved by the FDA and became available in the United States in 2008. The strips of the FreeStyle blood glucose monitoring system comprise a printed parallel plate coulometer, with a 50 microm gap between two facing printed electrodes, a carbon electrode and a Ag/AgCl electrode. The volume of blood between the facing plates is accurately controlled. The glucose is electrooxidized through catalysis by a glucose dehydrogenase (GDH) and an Os(2+/3+) redox mediator, which is reduced by the glucose-reduced enzyme and is electrooxidized on the carbon electrode. Initially the system used pyrroloquinoline quinone (PQQ)-dependent GDH but now uses flavin adenine dinucleotide (FAD)-dependent GDH. Because the facing electrodes are separated by such a small distance, shuttling of electrons by the redox couple could interfere with the coulometric assay. However, the Os(2+/3+) redox mediator is selected to have a substantially negative formal potential, between 0.0 and -0.2 V, versus that of the facing Ag/AgCl electrode. This makes the flow of a shuttling current between the two electrodes virtually impossible because the oxidized Os(3+) complex cannot be appreciably reduced at the more positively poised Ag/AgCl electrode. The FreeStyle Navigator continuous glucose monitoring system uses a subcutaneously implanted miniature plastic sensor connected to a transmitter to measure glycemia amperometrically and sends the information to a PDA-like device every minute. The sensor consists of a narrow (0.6 mm wide) plastic substrate on which carbon-working, Ag/AgCl reference, and carbon counter electrodes are printed in a stacked geometry. The active wired enzyme sensing layer covers only about 0.1 mm(2) of the working electrode and is overlaid by a flux-limiting membrane. It resides at about 5 mm depth in the subcutaneous adipose tissue and monitors glucose concentrations over the range 20-500 mg/dL. Its core component, a miniature, disposable, amperometric glucose sensor, has an electrooxidation catalyst made from a crosslinked adduct of glucose oxidase (GOx) and a GOx wiring redox hydrogel containing a polymer-bound Os(2+/3+) complex. Because of the selectivity of the catalyst for glucose, very little current flows in the absence of glucose. That feature, either alone or in combination with other features of the sensor, facilitates the one-point calibration of the system. The sensor is implanted subcutaneously and replaced by the patient after 5 days use with minimal pain. The wearer does not feel its presence under the skin.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20384299     DOI: 10.1021/ar9002015

Source DB:  PubMed          Journal:  Acc Chem Res        ISSN: 0001-4842            Impact factor:   22.384


  21 in total

1.  Inhibition of carbohydrate and lipid digestive enzymes activities by Zygophyllum album extracts: effect on blood and pancreas inflammatory biomarkers in alloxan-induced diabetic rats.

Authors:  Kais Mnafgui; Mouna Kchaou; Khaled Hamden; Fatma Derbali; Sadok Slama; Mbarek Nasri; Hichem Ben Salah; Noureddine Allouche; Abdelfattah Elfeki
Journal:  J Physiol Biochem       Date:  2013-09-01       Impact factor: 4.158

2.  Metal-organic frameworks for the sorption of acetone and isopropanol in exhaled breath of diabetics prior to quantitation by gas chromatography.

Authors:  Li-Qing Yu; Fei-Hong Su; Meng-Yuan Ma; Yun-Kai Lv
Journal:  Mikrochim Acta       Date:  2019-07-31       Impact factor: 5.833

3.  Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy.

Authors:  Rishikesh Pandey; Santosh Kumar Paidi; Tulio A Valdez; Chi Zhang; Nicolas Spegazzini; Ramachandra Rao Dasari; Ishan Barman
Journal:  Acc Chem Res       Date:  2017-01-10       Impact factor: 22.384

4.  Label-free spectrochemical probe for determination of hemoglobin glycation in clinical blood samples.

Authors:  Rishikesh Pandey; Surya P Singh; Chi Zhang; Gary L Horowitz; Niyom Lue; Luis Galindo; Ramachandra R Dasari; Ishan Barman
Journal:  J Biophotonics       Date:  2018-06-19       Impact factor: 3.207

5.  Exceptionally small supramolecular hydrogelators based on aromatic-aromatic interactions.

Authors:  Junfeng Shi; Yuan Gao; Zhimou Yang; Bing Xu
Journal:  Beilstein J Org Chem       Date:  2011-02-07       Impact factor: 2.883

6.  Electrochemical Sensing and Imaging Based on Ion Transfer at Liquid/Liquid Interfaces.

Authors:  Shigeru Amemiya; Jiyeon Kim; Anahita Izadyar; Benjamin Kabagambe; Mei Shen; Ryoichi Ishimatsu
Journal:  Electrochim Acta       Date:  2013-11-01       Impact factor: 6.901

Review 7.  Transforming the blood glucose meter into a general healthcare meter for in vitro diagnostics in mobile health.

Authors:  Tian Lan; Jingjing Zhang; Yi Lu
Journal:  Biotechnol Adv       Date:  2016-03-03       Impact factor: 14.227

8.  Substrate specificity and interferences of a direct-electron-transfer-based glucose biosensor.

Authors:  Alfons K G Felice; Christoph Sygmund; Wolfgang Harreither; Roman Kittl; Lo Gorton; Roland Ludwig
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

Review 9.  Materials for diabetes therapeutics.

Authors:  Kaitlin M Bratlie; Roger L York; Michael A Invernale; Robert Langer; Daniel G Anderson
Journal:  Adv Healthc Mater       Date:  2012-04-05       Impact factor: 9.933

10.  Oxidase-loaded hydrogels for versatile potentiometric metabolite sensing.

Authors:  Nicole L Walker; Jeffrey E Dick
Journal:  Biosens Bioelectron       Date:  2021-01-17       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.