Literature DB >> 20379013

Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions.

Masahiro Iijima1, Toshihiro Yuasa, Kazuhiko Endo, Takeshi Muguruma, Hiroki Ohno, Itaru Mizoguchi.   

Abstract

This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss). Non ion implanted nickel-titanium wire (Neo Sentalloy) was used as control. The anodic corrosion behavior was examined by potentiodynamic polarization measurement. The surfaces of the specimens were examined with SEM. The elemental depth profiles were characterized by XPS. Neo Sentalloy Ionguard in artificial saliva and Butler F Mouthrinse (500 ppm) had a lower current density than Neo Sentalloy. In addition, breakdown potential of Neo Sentalloy Ionguard in Ora-Bliss (900 ppm) was much higher than that of Neo Sentalloy although both wires had similar corrosion potential in Ora-Bliss (450 and 900 ppm). The XPS results for Neo Sentalloy Ionguard suggested that the layers consisted of TiO(2) and TiN were present on the surface and the layers may improve the corrosion properties.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20379013     DOI: 10.4012/dmj.2009-069

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

Authors:  Roberto Rongo; Gianluca Ametrano; Antonio Gloria; Gianrico Spagnuolo; Angela Galeotti; Sergio Paduano; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2013-12-05       Impact factor: 2.079

2.  Gradient control of the adhesive force between Ti/TiO2 nanotubular arrays fabricated by anodization.

Authors:  Minghui Zhao; Jidong Li; Yubao Li; Jian Wang; Yi Zuo; Jiaxing Jiang; Huanan Wang
Journal:  Sci Rep       Date:  2014-11-24       Impact factor: 4.379

3.  Effect of Different Types of Toothpaste on the Frictional Resistance Between Orthodontic Stainless Steel Brackets and Wires.

Authors:  Tahereh Hosseinzadeh Nik; Tabassom Hooshmand; Homa Farhadifard
Journal:  J Dent (Tehran)       Date:  2017-09

4.  Effect of chlorhexidine-containing prophylactic agent on the surface characterization and frictional resistance between orthodontic brackets and archwires: an in vitro study.

Authors:  Tahereh Hosseinzadeh Nik; Tabassom Hooshmand; Habibeh Farazdaghi; Arash Mehrabi; Elham S Emadian Razavi
Journal:  Prog Orthod       Date:  2013-11-20       Impact factor: 2.750

5.  Ion Release and Surface Changes of Nickel-Titanium Archwires Induced by Changes in the pH Value of the Saliva-Significance for Human Health Risk Assessment.

Authors:  Zana Jusufi Osmani; Borut Poljšak; Saša Zelenika; Ervin Kamenar; Kristina Marković; Marko Perčić; Višnja Katić
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.