Literature DB >> 20378276

Cross-sectional area and strength differences of fiberwire, prolene, and ticron sutures.

Peter Scherman1, Roger Haddad, Peter Scougall, William R Walsh.   

Abstract

PURPOSE: Flexor tendons should be repaired with suture material strong enough to permit early motion and small enough for the resulting knot to allow unimpeded tendon glide and healing. This study sought to define differences in cross-sectional area and knotted tensile strength among Fiberwire, Prolene, and Ticron sutures.
METHODS: Five strands, each of 3-0 and 4-0 Prolene, Ticron, and Fiberwire sutures, were embedded in polymethylmethacrylate and sectioned in a linear precision saw to obtain 10 cross-sections of each material and size. These were examined by scanning electron microscopy and digitally analyzed for cross-sectional areas. Ten strands of each suture material and size had a single throw knot placed, and they were loaded to failure in a micromechanical tester.
RESULTS: Prolene and Ticron cross-sections were circular. Fiberwire was noncircular. The 3-0 Fiberwire sutures had greater cross-sectional area than the 3-0 Ticron sutures (p < .001), which in turn were larger than 3-0 Prolene (p < .05). The 4-0 Fiberwire cross-sectional area was also greater than that of 3-0 Ticron and Prolene (p < .05). After relating knotted tensile strength to cross-sectional area, Fiberwire was 10% stronger than Prolene, and 25% stronger than Ticron.
CONCLUSIONS: Fiberwire is not only stronger, but also larger than other sutures in the same or even higher suture size category. Failure to meet the United States Pharmacopeia standards for suture diameter is declared in the product information sheet, although surgeons may not be aware of these size variations. Suture size definitions are currently based on diameter, a consistent measure for circular monofilament sutures, but not for braided or noncircular sutures. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20378276     DOI: 10.1016/j.jhsa.2010.02.005

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

Review 1.  Biomechanical comparison of double grasping repair versus cross-locked cruciate flexor tendon repair.

Authors:  C Liam Dwyer; D Dean Dominy; Timothy E Cooney; Richard Englund; Leonard Gordon; John D Lubahn
Journal:  Hand (N Y)       Date:  2015-03

2.  Does Barbed Suture Repair Negate the Benefit of Peripheral Repair in Porcine Flexor Tendon?

Authors:  Alan Sull; Serkan Inceoglu; Montri D Wongworawat
Journal:  Hand (N Y)       Date:  2016-03-09

3.  Comparison of surgical trends in zone 2 flexor tendon repair between Turkish and international surgeons.

Authors:  Seyyid Serif Unsal; Tugrul Yildirim; Mehmet Armangil
Journal:  Acta Orthop Traumatol Turc       Date:  2019-08-06       Impact factor: 1.511

4.  Wire fracture in postoperative Nuss procedure: a problem that cannot be ignored.

Authors:  Yunxuan Zhang; Qiang Chen; Yarui Luo; Chenyu Sun; Meng Chen; Na Wu; Yimin Xie
Journal:  Transl Pediatr       Date:  2021-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.