Literature DB >> 20378020

Electrochemical behaviour of titanium in ammine and stannous fluoride and chlorhexidine 0.2 percent mouthwashes.

A Quaranta1, L F Ronconi, F Di Carlo, I Vozza, M Quaranta.   

Abstract

Titanium (Ti) is widely used in dentistry. Fluorides at acid pH could destabilize Ti oxide and make it susceptible to corrosion. The behaviour of IV grade machined Ti disks in 5 electrolytic solutions: Fusayama artificial saliva (Fas), ammine fluoride-stannous fluoride (Am-SnF2), 0.2 percent Chlorexidine (CHX) 0.20 percent, Fas with 20 percent Am-SnF2, and Fas with 20 percent CHX, was evaluated. Open circuit potential Ecorr was determined by immersing Ti disks for 24 hours in an electrochemical cell containing the solutions, potential changes were measured until a stable value was obtained. Examination by Scanning Electronic Microscope and Energy Dispersive X-ray Analysis were then performed. One way ANOVA analysis showed a significant difference of Ecorr values regarding the 5 solutions (p less than 0.001). The highest values were observed for Fas (-37.6 mV), intermediate for Am-SnF2 (-81mV) and lowest for CHX (-87.6mV). SEM analysis of disks after polarization curve in CHX showed a marked localized corrosion, while the other solutions showed no considerable corrosive action on Ti surface. When considering corrosive potential range in oral cavity, Ti had an excellent behaviour on both antiseptics evaluated. The results obtained in this study will enable us to recommend the use of Am-SnF2 mouthwash for patients with dental implants.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20378020     DOI: 10.1177/039463201002300132

Source DB:  PubMed          Journal:  Int J Immunopathol Pharmacol        ISSN: 0394-6320            Impact factor:   3.219


  4 in total

1.  Cytotoxicity effect of orthodontic miniscrew-implant in different types of mouthwash: An in-vitro study.

Authors:  Wulan S Utami; Haru S Anggani; Maria Purbiati
Journal:  J Orthod Sci       Date:  2022-01-28

Review 2.  Teledentistry in the Management of Patients with Dental and Temporomandibular Disorders.

Authors:  Giuseppe Minervini; Diana Russo; Alan Scott Herford; Francesca Gorassini; Aida Meto; Cesare D'Amico; Gabriele Cervino; Marco Cicciù; Luca Fiorillo
Journal:  Biomed Res Int       Date:  2022-04-09       Impact factor: 3.246

3.  Commercial oral hygiene products and implant collar surfaces: Scanning electron microscopy observations.

Authors:  Serena Bianchi; Giulia Fantozzi; Sara Bernardi; Sevastiani Antonouli; Maria Adelaide Continenza; Guido Macchiarelli
Journal:  Can J Dent Hyg       Date:  2020-02-01

4.  Combination of toothbrushing and chlorhexidine compared with exclusive use of chlorhexidine to reduce the risk of ventilator-associated pneumonia: A systematic review with meta-analysis.

Authors:  Pedro Urquiza Jayme Silva; Luiz Renato Paranhos; Daniela Meneses-Santos; Cauane Blumenberg; Dhiancarlo Rocha Macedo; Sérgio Vitorino Cardoso
Journal:  Clinics (Sao Paulo)       Date:  2021-06-11       Impact factor: 2.365

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.