Literature DB >> 20376278

Potentials of Digitally Sampling Scintillation Pulses in Timing Determination in PET.

Qingguo Xie1, Chien-Min Kao, Xi Wang, Ning Guo, Caigang Zhu, Henry Frisch, William W Moses, Chin-Tu Chen.   

Abstract

We investigate the potentials of digitally sampling scintillation pulses techniques for positron emission tomography (PET) in this paper, focusing on the determination of the event time. We have built, and continue building, a digital library of PET event waveforms generated with various combinations of photo-detectors and scintillator materials, with various crystal sizes. Events in this digital library are obtained at a high sampling of 20 GSps (Giga-samples per second) so that their waveforms are recorded with high accuracy. To explore the potential advantages of digitally sampling scintillation pulses, we employ a dataset in the above-mentioned library to evaluate two methods for digitizing the event pulses and linear interpolation techniques to analyze the resulting digital samples. Our results show that the two digitization methods that we studied can yield a coincidence timing resolution of about 300 ps FWHM when applied to events generated by a pair of LSO + PMT detector units. This timing resolution is comparable with that is achieved by the same detector pair with a constant fraction discriminator (CFD). As a benchmark, regular-time sampling (RTS) method, usually implemented with very fast traditional analog-to-digital converters (ADCs) for digitizing scintillation pulses, is not feasible for a multi-channel system like a PET system. Digitizing scintillation pulses with multi-voltage threshold (MVT) method could be implemented at a reasonable cost for a PET system. With digitized PET event samples, various digital signal processing (DSP) techniques can be implemented to determine event arrival time. Our results have therefore demonstrated the promising potentials of digitally sampling scintillation pulses techniques in PET imaging.

Entities:  

Year:  2009        PMID: 20376278      PMCID: PMC2849149          DOI: 10.1109/TNS.2009.2023656

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  2 in total

1.  Real-time cardiac MRI using DSP's.

Authors:  P N Morgan; R J Iannuzzelli; F H Epstein; R S Balaban
Journal:  IEEE Trans Med Imaging       Date:  1999-07       Impact factor: 10.048

2.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Authors:  Suleman Surti; Austin Kuhn; Matthew E Werner; Amy E Perkins; Jeffrey Kolthammer; Joel S Karp
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

  2 in total
  3 in total

1.  Artifacts in digital coincidence timing.

Authors:  W W Moses; Q Peng
Journal:  Phys Med Biol       Date:  2014-10-16       Impact factor: 3.609

2.  Using convolutional neural networks to estimate time-of-flight from PET detector waveforms.

Authors:  Eric Berg; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

3.  New Digital Plug and Imaging Sensor for a Proton Therapy Monitoring System Based on Positron Emission Tomography.

Authors:  Nicola D'Ascenzo; Min Gao; Emanuele Antonecchia; Paolo Gnudi; Hsien-Hsin Chen; Fang-Hsin Chen; Ji-Hong Hong; Ing-Tsung Hsiao; Tzu-Chen Yen; Weidong Wang; Daoming Xi; Bo Zhang; Qingguo Xie
Journal:  Sensors (Basel)       Date:  2018-09-08       Impact factor: 3.576

  3 in total