Literature DB >> 20373154

Ultrasound guidance for internal jugular vein cannulation: Continuing Professional Development.

Christian Ayoub1, Catherine Lavallée, André Denault.   

Abstract

PURPOSE: The objective of this continuing professional development module is to describe the role of ultrasound for central venous catheterization and to specify its benefits and limitations. Although ultrasound techniques are useful for all central venous access sites, the focus of this module is on the internal jugular vein approach. PRINCIPAL
FINDINGS: In recent years, several studies were published on the benefits of ultrasound use for central venous catheterization. This technique has evolved rapidly due to improvements in the equipment and technology available. Ultrasound helps to detect the anatomical variants of the internal jugular vein. The typical anterolateral position of the internal jugular vein with respect to the carotid is found in only 9-92% of cases. Ultrasound guidance reduces the rate of mechanical, infectious, and thrombotic complications by 57%, and it also reduces the failure rate by 86%. Cost-benefit analyses show that the cost of ultrasound equipment is compensated by the decrease in the expenses associated with the treatment of complications. In this article, we will review the history of ultrasound guidance as well as the reasons that account for its superiority over the classical anatomical landmark technique. We will describe the equipment needed for central venous catheterization as well as the various methods to visualize with ultrasound.
CONCLUSION: To improve patient safety, we recommend the use of ultrasound for central venous catheterization using the internal jugular approach.

Entities:  

Mesh:

Year:  2010        PMID: 20373154     DOI: 10.1007/s12630-010-9291-7

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  3 in total

1.  Internal jugular vein thrombosis associated with venous hypoplasia and protein S deficiency revealed by ultrasonography.

Authors:  Byung Gun Lim; Young Min Kim; Heezoo Kim; Sang Ho Lim; Mi Kyoung Lee
Journal:  J Anesth       Date:  2011-09-20       Impact factor: 2.078

2.  A novel technique for ultrasound-guided central venous catheterization under short-axis out-of-plane approach: "stepwise flashing with triangulation".

Authors:  Toshinori Horiuchi; Chie Okuda; Naoko Kurita; Ayako Yamaguchi; Kazuhiko Kitagawa; Masafumi Takeda; Keiichi Sha; Toshihiro Nagahata
Journal:  J Anesth       Date:  2017-06-20       Impact factor: 2.078

3.  From the simulation center to the bedside: Validating the efficacy of a dynamic haptic robotic trainer in internal jugular central venous catheter placement.

Authors:  Hong-En Chen; Cheyenne C Sonntag; Katelin A Mirkin; David F Pepley; David C Han; Jason Z Moore; Scarlett R Miller
Journal:  Am J Surg       Date:  2019-10-21       Impact factor: 2.565

  3 in total