Literature DB >> 20371909

Development of a new RF coil and gamma-ray radiation shielding assembly for improved MR image quality in SPECT/MRI.

Seunghoon Ha1, Mark J Hamamura, Werner W Roeck, L Tugan Muftuler, Orhan Nalcioglu.   

Abstract

Magnetic resonance (MR)-based multimodality imaging systems, such as single-photon emission tomography (SPECT)/magnetic resonance imaging (MRI) or positron emission tomography (PET)/MRI, face many difficulties because of problems with the compatibility of the nuclear detector system with the MR system. However, several studies have reported on the design considerations of MR-compatible nuclear detectors for combined SPECT/MRI. In this study, we developed a new radiofrequency (RF) coil and gamma-ray radiation shielding assembly to advance the practical implementation of SPECT/MRI in providing high sensitivity while minimizing the interference between the MRI and SPECT systems. The proposed assembly consists of a three-channel receive-only RF coil and gamma-ray radiation shields made of a specialized lead composite powder designed to reduce conductivity and thus minimizing any effect on the magnetic field arising from the induced eddy currents. A conventional birdcage RF coil was also tested for comparison with the proposed RF coil. Quality (Q)-factors were measured using both RF coils without any shielding, with solid lead shielding, and with our composite lead shielding. Signal-to-noise ratios (SNRs) were calculated using 4 T MR images of phantoms both with and without the new gamma-ray radiation shields. The Q-factor and SNR measurements demonstrate the improved MRI performance due to the new RF coil/gamma-ray radiation shield assembly designed for SPECT/MRI, making it a useful addition to multimodality imaging technology not only for animal studies but also for in vivo study of humans.

Entities:  

Mesh:

Year:  2010        PMID: 20371909     DOI: 10.1088/0031-9155/55/9/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  In vivo validation of quantitative frequency domain fluorescence tomography.

Authors:  Yuting Lin; Michael Ghijsen; Orhan Nalcioglu; Gultekin Gulsen
Journal:  J Biomed Opt       Date:  2012-12       Impact factor: 3.170

2.  A SPECT Camera for Combined MRI and SPECT for Small Animals.

Authors:  D Meier; D J Wagenaar; S Chen; J Xu; J Yu; B M W Tsui
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-10-01       Impact factor: 1.455

3.  Feasibility study of a unilateral RF array coil for MR-scintimammography.

Authors:  Seunghoon Ha; Mark J Hamamura; Werner W Roeck; James Hugg; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Phys Med Biol       Date:  2011-10-05       Impact factor: 3.609

4.  Initial Investigation of preclinical integrated SPECT and MR imaging.

Authors:  Mark J Hamamura; Seunghoon Ha; Werner W Roeck; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Technol Cancer Res Treat       Date:  2010-02

5.  (⁹⁹m)Tc-bisphosphonate-iron oxide nanoparticle conjugates for dual-modality biomedical imaging.

Authors:  Rafael Torres Martin de Rosales; Richard Tavaré; Arnaud Glaria; Gopal Varma; Andrea Protti; Philip J Blower
Journal:  Bioconjug Chem       Date:  2011-02-21       Impact factor: 4.774

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.