Literature DB >> 2036778

Alignment of ventilation and gas fraction for breath-by-breath respiratory gas exchange calculations in exercise.

R L Hughson1, D R Northey, H C Xing, B H Dietrich, J E Cochrane.   

Abstract

The effects of correct alignment of the ventilation and fractional gas concentration during breath-by-breath calculation of oxygen uptake (VO2) have been examined during exercise in four subjects, at each of 50, 100, 150, and 200 W. Data were analyzed using lagtimes in the range of 200 to 400 msec to align ventilation with gas fraction. VO2 was markedly affected by lagtime. Calculated values of VO2 at 200 W ranged from 1953 +/- 55 (mean +/- SEM), to 2583 +/- 29, to 2843 +/- 28 ml.min-1 with lagtimes of 200, 310, and 400 msec, respectively. Mean values from a mixing box system did not differ significantly from the mean of the breath-by-breath data collection with a lagtime of 310 msec. Additional computations have shown that temperature correction can markedly affect calculated ventilatory volumes and N2 balance. VO2 was not changed because of the compensation from the calculated effects of changes in lung gas stores.

Entities:  

Mesh:

Year:  1991        PMID: 2036778     DOI: 10.1016/0010-4809(91)90024-q

Source DB:  PubMed          Journal:  Comput Biomed Res        ISSN: 0010-4809


  7 in total

Review 1.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

2.  Kinetics of ventilation and gas exchange during supine and upright cycle exercise.

Authors:  R L Hughson; H C Xing; C Borkhoff; G C Butler
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

Review 3.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

4.  Oxygen uptake versus exercise intensity: a new concept in assessing cardiovascular exercise function in patients with congenital heart disease.

Authors:  T Reybrouck; L Mertens; S Brusselle; M Weymans; B Eyskens; J Defoor; M Gewillig
Journal:  Heart       Date:  2000-07       Impact factor: 5.994

Review 5.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

6.  Exploration of an Inflection Point of Ventilation Parameters with Anaerobic Threshold Using Strucchange.

Authors:  Takenori Aida; Akira Shionoya; Hirofumi Nonaka; Kouji Hayami; Hisashi Uchiyama; Masahiro Nagamori; Satoshi Ohhashi; Mai Kobayashi; Tsugumi Takayama; Shinji Kimura
Journal:  Sensors (Basel)       Date:  2022-03-31       Impact factor: 3.576

7.  Disadvantages of Automated Respiratory Gas Exchange Analyzers.

Authors:  Juan José Ramos-Álvarez; Irma Lorenzo-Capellá; Francisco Javier Calderón-Montero
Journal:  Front Physiol       Date:  2020-02-07       Impact factor: 4.566

  7 in total