Literature DB >> 20363395

Significance of data treatment and experimental setup on the determination of copper complexing parameters by anodic stripping voltammetry.

Dario Omanović1, Cédric Garnier, Yoann Louis, Véronique Lenoble, Stéphane Mounier, Ivanka Pizeta.   

Abstract

Different procedures of voltammetric peak intensities determination, as well as various experimental setups were systematically tested on simulated and real experimental data in order to identify critical points in the determination of copper complexation parameters (ligand concentration and conditional stability constant) by anodic stripping voltammetry (ASV). Varieties of titration data sets (Cu(measured)vs. Cu(total)) were fitted by models encompassing discrete sites distribution of one-class and two-class of binding ligands (by PROSECE software). Examination of different procedures for peak intensities determination applied on voltammograms with known preset values revealed that tangent fit (TF) routine should be avoided, as for both simulated and experimental titration data it produced an additional class of strong ligand (actually not present). Peak intensities determination by fitting of the whole voltammogram was found to be the most appropriate, as it provided most reliable complexation parameters. Tests performed on real seawater samples under different experimental conditions revealed that in addition to importance of proper peak intensities determination, an accumulation time (control of the sensitivity) and an equilibration time needed for complete complexation of added copper during titration (control of complexation kinetics) are the keypoints to obtain reliable results free of artefacts. The consequence of overestimation and underestimation of complexing parameters is supported and illustrated by the example of free copper concentrations (the most bioavailable/toxic specie) calculated for all studied cases. Errors up to 80% of underestimation of free copper concentration and almost two orders of magnitude overestimation of conditional stability constant were registered for the simulated case with two ligands. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Year:  2010        PMID: 20363395     DOI: 10.1016/j.aca.2010.02.008

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  The Application of Curve Fitting on the Voltammograms of Various Isoforms of Metallothioneins-Metal Complexes.

Authors:  Miguel Angel Merlos Rodrigo; Jorge Molina-López; Ana Maria Jimenez Jimenez; Elena Planells Del Pozo; Pavlina Adam; Tomas Eckschlager; Ondrej Zitka; Lukas Richtera; Vojtech Adam
Journal:  Int J Mol Sci       Date:  2017-03-11       Impact factor: 5.923

2.  Aqueous copper bioavailability linked to shipwreck-contaminated reef sediments.

Authors:  Adam Hartland; Rebecca Zitoun; Rob Middag; Sylvia Sander; Alix Laferriere; Huma Saeed; Sharon De Luca; Philip M Ross
Journal:  Sci Rep       Date:  2019-07-02       Impact factor: 4.379

3.  Organic Copper Speciation by Anodic Stripping Voltammetry in Estuarine Waters With High Dissolved Organic Matter.

Authors:  Jasmin Pađan; Saša Marcinek; Ana-Marija Cindrić; Chiara Santinelli; Simona Retelletti Brogi; Olivier Radakovitch; Cédric Garnier; Dario Omanović
Journal:  Front Chem       Date:  2021-02-02       Impact factor: 5.221

  3 in total