Literature DB >> 20362847

Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism: one-year follow-up.

José F Alfonso1, Luis Fernández-Vega, Paulo Fernandes, José M González-Méijome, Robert Montés-Micó.   

Abstract

PURPOSE: To assess the predictability, efficacy, safety, and stability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct moderate to high myopic astigmatism.
SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain.
METHODS: This study comprised eyes that had implantation of a toric Intraocular Collamer Lens for moderate to high myopic astigmatism. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse events were evaluated over 12 months.
RESULTS: Preoperatively, the mean sphere in the 55 eyes was -4.65 diopters (D) +/- 3.02 (SD) (range -0.50 to -12.50 D) and the mean cylinder, -3.03 +/- 0.79 D (range -1.25 to -4.00 D). At 12 months, the mean Snellen decimal UDVA was 0.80 +/- 0.20 and the mean CDVA, 0.85 +/- 0.18; 62.0% of eyes had a CDVA of 20/20. More than 50.0% of eyes gained 1 or more lines of CDVA. The treatment was highly predictable for spherical equivalent (SE) (r(2) = 0.99) and astigmatic components J0 (r(2) = 0.97) and J45 (r(2) = 0.99). Of the eyes, 94.5% were within +/-0.50 D of the attempted SE and all were within +/-1.00 D. For J0, 94.5% of eyes were within +/-0.50 D and for J45, 98.2% of eyes; all eyes were within +/-1.00 D. The efficacy index was 0.95 at 3 months and 1.08 at 1 year.
CONCLUSIONS: The UDVA and CDVA with toric pIOLs were good and highly stable over 12 months, confirming the procedure is safe, predictable, and effective for correction of moderate to high astigmatic. Copyright (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20362847     DOI: 10.1016/j.jcrs.2009.10.052

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCT.

Authors:  Jose F Alfonso; L Fernández-Vega; C Lisa; P Fernandes; J González-Meijome; R Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-28       Impact factor: 3.117

2.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

3.  Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up.

Authors:  Esin Sogutlu Sari; David P Pinero; Anil Kubaloglu; Pinar Sorgun Evcili; Arif Koytak; Isil Kutlutürk; Yusuf Ozerturk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-10       Impact factor: 3.117

4.  Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

Authors:  J F Alfonso; C Lisa; L Fernández-Vega Cueto; P Fernandes; J M González-Méijome; R Montés Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

5.  Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Aya Saito; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

6.  Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes.

Authors:  Erik L Mertens
Journal:  Clin Ophthalmol       Date:  2011-03-14

7.  Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism: Consort-Compliant Article.

Authors:  Kimiya Shimizu; Kazutaka Kamiya; Akihito Igarashi; Hidenaga Kobashi
Journal:  Medicine (Baltimore)       Date:  2016-04       Impact factor: 1.889

8.  Comparison of Visian toric collamer lens and toric acrylic intraocular lens implantation for the treatment of myopia with astigmatism.

Authors:  Hatem Ammar; Mohamed Anbar; Marwa M Abdellah
Journal:  Clin Ophthalmol       Date:  2016-12-29

9.  Three-year follow-up of posterior chamber toric phakic intraocular lens implantation for moderate to high myopic astigmatism.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Hidenaga Kobashi; Akihito Igarashi; Mari Komatsu
Journal:  PLoS One       Date:  2013-02-08       Impact factor: 3.240

10.  Optical quality of hyperopic and myopic phakic intraocular lenses.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; David Madrid-Costa; Robert Montés-Micó
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.