Literature DB >> 20362843

Contrast sensitivity measurement with 2 contrast sensitivity tests in normal eyes and eyes with cataract.

Young Taek Hong1, Sang Woo Kim, Eung Kweon Kim, Tae-im Kim.   

Abstract

PURPOSE: To assess the reliability of and correlation between 2 contrast sensitivity tests in normal eyes and eyes with cataract.
SETTING: Department of Ophthalmology, Yonsei University Hospital, Seoul, Korea.
METHODS: The Vision Contrast Test System (wall-chart test) and Optec 6500 system (view-in test) were used to measure contrast sensitivity in normal eyes at 2 visits separated by 2 weeks and in eyes with cataract before and 2 months after cataract surgery. The test-retest reliability and correlation were calculated by the intraclass correlation coefficient (ICC), coefficient of repeatability (COR), and 95% range of difference using the Bland-Altman method.
RESULTS: The study evaluated 40 normal eyes of 20 subjects and 44 eyes of 38 cataract patients. The repeatability of the 2 test methods was generally acceptable. The view-in test performed better than the wall-chart test in the ICC analysis (0.85 versus 0.65) but not in the COR analysis (+/-0.20 log versus +/-0.27 log). Correlation between the 2 tests was poor in both groups of eyes. The ceiling effect was greater with the wall-chart test. The floor effect occurred mainly in patients with cataract, in which it was greater preoperatively than postoperatively; at high frequency; and with the view-in test.
CONCLUSION: Based on the ceiling and floor effect, the view-in test is better for detecting subtle contrast sensitivity changes in normal or near-normal eyes and the wall-chart test is useful in eyes with compromised vision. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Copyright (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20362843     DOI: 10.1016/j.jcrs.2009.10.048

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Impact of cataract surgery on vision-related life performances: the usefulness of Real-Life Vision Test for cataract surgery outcomes evaluation.

Authors:  W Ni; X Li; Z Hou; H Zhang; W Qiu; W Wang
Journal:  Eye (Lond)       Date:  2015-08-14       Impact factor: 3.775

2.  How accurate is an LCD screen version of the Pelli-Robson test?

Authors:  Fabrizio Zeri; Paolo Calcatelli; Eleonora Funaro; Marialuisa Martelli; Shehzad A Naroo
Journal:  Int Ophthalmol       Date:  2017-06-21       Impact factor: 2.031

3.  Using the real-life vision test to assess the functional vision of age-related cataract patients.

Authors:  W Ni; X Li; M Ao; H Zhang; Z Hou; S Si; W Wang
Journal:  Eye (Lond)       Date:  2012-08-10       Impact factor: 3.775

4.  Comparison of Two Different Contrast Sensitivity Testing Methods in Patients with Low Vision.

Authors:  Deniz Altinbay; Esra Sahli; Aysun Idil
Journal:  J Curr Ophthalmol       Date:  2022-04-16

5.  Evaluation of contrast sensitivity measurements after retrobulbar optic neuritis in Multiple Sclerosis.

Authors:  Marta Owidzka; Michal Wilczynski; Wojciech Omulecki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-02-28       Impact factor: 3.117

6.  Different Impacts of Luminosity on Contrast Vision in Eyes with Transparent Optic Media and with Cataract Simulation.

Authors:  Adrian Smedowski; Karolina Mikus-Zagorska; Agnieszka Jakubowska; Anna Piotrowska-Gwozdz; Agnieszka Piotrowska-Seweryn; Patrycja Orchel; Dorota Pojda-Wilczek
Journal:  Med Princ Pract       Date:  2015-06-26       Impact factor: 1.927

7.  Comparison of two methods for measuring contrast sensitivity in anisometropic amblyopia.

Authors:  Alireza Mohammadi; Hassan Hashemi; Ali Mirzajani; Abbasali Yekta; Ebrahim Jafarzadehpur; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2018-04-27

8.  A randomized phase 2 clinical trial of phentolamine mesylate eye drops in patients with severe night vision disturbances.

Authors:  Jay Pepose; Mitchell Brigell; Eliot Lazar; Curtis Heisel; Jonah Yousif; Kavon Rahmani; Ajay Kolli; Min Hwang; Cara Mitrano; Audrey Lazar; Konstantinos Charizanis; Mina Sooch; Marguerite McDonald
Journal:  BMC Ophthalmol       Date:  2022-10-08       Impact factor: 2.086

9.  Precision and Normative Values of a New Computerized Chart for Contrast Sensitivity Testing.

Authors:  Giacomo Savini; Antonio Calossi; Domenico Schiano-Lomoriello; Piero Barboni
Journal:  Sci Rep       Date:  2019-11-12       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.