Literature DB >> 20362829

Anterior cruciate ligament tibial guide pin accuracy and surgical precision: comparing 3.0-mm and 2.4-mm guide pins.

James H Lubowitz1.   

Abstract

PURPOSE: The purpose of this study was to evaluate the accuracy of a 3.0-mm-diameter anterior cruciate ligament (ACL) tibial guide pin versus a standard, 2.4-mm drill-tipped guide pin. A secondary purpose was to evaluate surgeon precision in identifying the true (anatomic) center of the ACL tibial footprint using arthroscopic visualization.
METHODS: Five matched pairs of cadaveric knees were disarticulated, leaving a well-defined footprint of the ACL on the tibial plateau. The tibial footprint was digitally recorded by a bioengineer, and the true center of the footprint was calculated. Next, using arthroscopic visualization, a surgeon identified and marked his estimation of the true center of the ACL tibial footprint. This mark was then digitally recorded by the bioengineer and compared with the calculated center, allowing quantification of surgeon anatomic precision. Finally, under arthroscopic visualization, the surgeon was given 1 attempt to aim and drill the guide pin to his mark. Pin position was digitally recorded; the distance of the drill pin from the mark quantifies drill pin placement accuracy.
RESULTS: Mean accuracy for the 3.0-mm guide pin was 2.87 +/- 1.19 mm versus 6.98 +/- 1.29 mm for the 2.4-mm pin. The difference was significant (P = .005). Surgeon anatomic precision was 3.32 +/- 2.10 mm.
CONCLUSIONS: Our results show that a 3-mm ACL tibial guide pin is significantly more accurate than a 2.4-mm-diameter pin. The 3-mm pin accuracy is within the range of surgeon precision; the 2.4-mm pin accuracy is not. CLINICAL RELEVANCE: Pin accuracy and surgeon precision are clinically relevant measures because anatomic tunnel placement is a determinant of ACL reconstruction outcome. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20362829     DOI: 10.1016/j.arthro.2009.08.028

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  1 in total

1.  Surgical Adjustment of the Guide Pin to Perform a Correct Tibial Tunnel in Anatomical Anterior Cruciate Ligament Single-Bundle Reconstruction.

Authors:  Bharath S Kumar; Renato Andrade; Ana Leal; André Sarmento; Hélder Pereira; Nuno Sevivas; João Espregueira-Mendes
Journal:  Arthrosc Tech       Date:  2016-07-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.