Literature DB >> 20362822

Biomechanical comparison of transosseous versus suture anchor repair of the subscapularis tendon.

Daniel J Wheeler1, Tigran Garabekyan, Roberto Lugo, Jenni M Buckley, Christopher Jones, Marielena Lotz, Jeffery C Lotz, C Benjamin Ma.   

Abstract

PURPOSE: The purpose of this study was to compare the biomechanical properties of transosseous versus suture anchor repair of the subscapularis tendon. We also performed real-time measurement of contact area and pressure of the repair site under rotational loads.
METHODS: Six paired human cadaveric shoulders were subjected to rotational loading after repair of the subscapularis tendon. Both shoulders were randomized to transosseous or suture anchor repairs. Real-time pressure sensors were placed between the subscapularis tendon and lesser tuberosity. The repair was subjected to cyclical rotational loading and load-to-failure testing.
RESULTS: No significant difference was detected in initial pressurized contact area between transosseous repairs (1.70 +/- 0.99 cm(2), 57.88 +/- 30.02% footprint) and suture anchor repairs (1.08 +/- 0.58 cm(2), 34.26% +/- 17.32% footprint). Under cyclical loading, the conditioning elongation of transosseous repairs (0.64 +/- 0.40 mm) was significantly lower (P < .05) than that of suture anchor repairs (2.38 +/- 1.58 mm). No significant difference was found in mean pressurized contact area between the transosseous repairs (2.72 +/- 1.25 cm(2), 94.2% +/- 37.4% footprint) and suture anchor repairs (2.01 +/- 0.89 cm(2), 65.9% +/- 27.9% footprint). For suture anchor repairs, repair-site contact area was significantly (P < .05) smaller than the area of corresponding native insertional footprints; for transosseous repairs, no significant difference was detected. There were no significant differences in peak pressures between the 2 repairs. In the load-to-failure tensile test, there was no significant difference between transosseous repairs (453.2 +/- 66.1 N) and suture anchor repairs (392.6 +/- 78.0 N).
CONCLUSIONS: Transosseous and suture anchor repairs of the subscapularis tendon have comparable biomechanical properties. Despite increased conditioning elongation in suture anchor repairs, we found no significant differences in mean contact area between the 2 repairs under cyclical loading. The suture anchor repairs do have a smaller contact area than the native insertional area. Real-time pressure and contact area measurements enabled mapping of the repair site throughout cyclical loading. CLINICAL RELEVANCE: Rotational loading of the subscapularis tendon may provide a more accurate representation of subscapularis tendon injuries. Both techniques showed adequate repair strength; however, neither surgical technique exhibited normal insertional behavior in this time-zero biomechanical study. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20362822     DOI: 10.1016/j.arthro.2009.08.026

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

1.  Transosseous Acetabular Labral Repair as an Alternative to Anchors.

Authors:  Luis Pérez-Carro; Andres Gonzalez Cabello; Mohamed Ibrahim Rakha; Sarthak Patnaik; Elias Centeno; Victor Miranda; Ana Alfonso Fernández
Journal:  Arthrosc Tech       Date:  2015-09-07

2.  [Arthroscopic double-row reconstruction of high-grade subscapularis tendon tears].

Authors:  F Plachel; S Pauly; P Moroder; M Scheibel
Journal:  Oper Orthop Traumatol       Date:  2018-03-22       Impact factor: 1.154

Review 3.  Limited Biomechanical Evidence Behind Single Row Versus Double Row Repair of Subscapularis Tears: A Systematic Review.

Authors:  Michelle Xiao; Samuel A Cohen; Emilie V Cheung; Seth L Sherman; Geoffrey D Abrams; Michael T Freehill
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-03-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.