Literature DB >> 20362724

Quantitative myocardial blush grade for the detection of cardiac allograft vasculopathy.

Grigorios Korosoglou1, Nina Riedle, Markus Erbacher, Thomas J Dengler, Christian Zugck, Wolfgang Rottbauer, Stefan Hardt, Raffi Bekeredjian, Arnt Kristen, Evangelos Giannitsis, Neal F Osman, Hartmut Dickhaus, Hugo A Katus.   

Abstract

BACKGROUND: Cardiac allograft vasculopathy (CAV) progressively compromises microvascular perfusion and function in heart transplantation (HTx)-recipients. The aim of our study was to investigate the ability of quantitative myocardial blush grade (MBG) to detect CAV.
METHODS: In consecutive HTx-recipients (n = 72) who underwent surveillance cardiac catheterization, MBG was assessed visually and quantitatively, by analyzing the time course of contrast agent intensity rise. Hereby, the parameter G(max)/T(max) was calculated as the plateau of grey-level intensity (G(max)) divided by the time-to-peak intensity (T(max)). HTx-recipients and 18 healthy volunteers underwent cardiac magnetic resonance, to assess diastolic strain rates and myocardial perfusion reserve during pharmacologic hyperemia.
RESULTS: Significant correlations were observed between G(max)/T(max) with perfusion reserve and with mean diastolic strain rates (r(2) = 0.68 and r(2) = 0.58, P < .001 for both). Visual and quantitative MBG using a cutoff value of G(max)/T(max) = 2.7/s yielded significantly higher accuracy than stenosis severity on coronary angiograms for the detection of impaired microvascular integrity as a surrogate marker for CAV (AUC = 0.78, SE = 0.06, 95% CI = 0.66-0.87 for lumen narrowing versus AUC = 0.91, SE = 0.03, 95%CI = 0.84-0.97 for G(max)/T(max); P < .01). Furthermore, quantitative MBG provided more robust prediction of survival (chi(2)= 14.0, P < .001), compared to visually estimated blush (chi(2)= 5.4, P = .02) and to coronary lumen narrowing assessment, (chi(2)= 4.8, P = .04).
CONCLUSIONS: Quantification of MBG can be performed on coronary angiograms of HTx-recipients, and may help with the identification of early CAV in patients with impaired perfusion reserve but without angiographically evident atherosclerosis. Copyright 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20362724     DOI: 10.1016/j.ahj.2009.12.023

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

Review 1.  Transplant allograft vasculopathy: Role of multimodality imaging in surveillance and diagnosis.

Authors:  Gregory A Payne; Fadi G Hage; Deepak Acharya
Journal:  J Nucl Cardiol       Date:  2015-12-28       Impact factor: 5.952

Review 2.  Quantitative assessment of myocardial blush grade in patients with coronary artery disease and in cardiac transplant recipients.

Authors:  Nina Patricia Hofmann; Hartmut Dickhaus; Hugo A Katus; Grigorios Korosoglou
Journal:  World J Cardiol       Date:  2014-10-26

Review 3.  Multi-modal imaging of the pediatric heart transplant recipient.

Authors:  Jonathan H Soslow; Margaret M Samyn
Journal:  Transl Pediatr       Date:  2019-10

4.  Evolving concepts and treatment strategies for cardiac allograft vasculopathy.

Authors:  Rodolfo Denadai Benatti; David O Taylor
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-01
  4 in total