Literature DB >> 20362708

Meta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplasty.

Fausto Biancari1, Vito D'Andrea, Carlo Di Marco, Grazia Savino, Valentina Tiozzo, Antonio Catania.   

Abstract

BACKGROUND: The aim of this meta-analysis was to evaluate the safety and efficacy of vascular closure devices (VCDs).
METHODS: This meta-analysis was performed in accordance with the Cochrane Handbook for Systematic Reviews.
RESULTS: The literature search yielded 31 prospective, randomized studies including 7,528 patients who were randomized to VCDs or manual/mechanical compression after diagnostic angiography and/or endovascular procedures. Most of these studies have excluded patients at high risk of puncture site complications. Meta-analysis showed similar results in the study groups in terms of groin hematoma, bleeding, pseudoaneurysm, and blood transfusion. Lower limb ischemia and other arterial ischemic complications (0.3% vs 0%, P = .07) as well as need of surgery for vascular complications (0.7% vs 0.4%, P = .10) were somewhat more frequent with arterial puncture closure devices. The incidence of groin infection was significantly more frequent with VCDs (0.6% vs 0.2%, P = .02). The use of VCD was uniformly associated with a significantly shorter time to hemostasis. Such differences where more evident in patients undergoing percutaneous coronary intervention, whereas these methods were associated with similar rates of adverse events among patients undergoing diagnostic coronary angiography.
CONCLUSIONS: The use of VCDs is associated with a significantly shorter time to hemostasis and thus may shorten recovery. However, the use of VCDs is associated with a somewhat increased risk of infection, lower limb ischemia/arterial stenosis/device entrapment in the artery, and need of vascular surgery for arterial complications. Further studies are needed to get more conclusive results, particularly in patients at high risk of femoral puncture-related complications. Copyright 2010 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20362708     DOI: 10.1016/j.ahj.2009.12.027

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  33 in total

1.  Radioembolization complicated by dissection of the common femoral artery.

Authors:  Sarah G Deitch; Ramona Gupta
Journal:  Semin Intervent Radiol       Date:  2011-06       Impact factor: 1.513

2.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

Review 3.  Access and hemostasis: femoral and popliteal approaches and closure devices-why, what, when, and how?

Authors:  Iacopo Barbetta; Jos C van den Berg
Journal:  Semin Intervent Radiol       Date:  2014-12       Impact factor: 1.513

4.  Development, preclinical evaluation and validation of a novel quick vascular closure device for transluminal, cardiac and radiological arterial catheterization.

Authors:  C Linti; M Doser; H Planck; S Oberhoffner; E Mueller; M Renardy; J Biesinger; B Neumann; K Stang; T O Greiner; C Schlensak; S Krajewski; H P Wendel
Journal:  J Mater Sci Mater Med       Date:  2018-06-11       Impact factor: 3.896

Review 5.  Vascular access and closure in coronary angiography and percutaneous intervention.

Authors:  Robert A Byrne; Salvatore Cassese; Maryam Linhardt; Adnan Kastrati
Journal:  Nat Rev Cardiol       Date:  2012-11-27       Impact factor: 32.419

6.  Safety and efficiency of femoral artery access closure with a novel biodegradable closure device: a prospective single-centre pilot study.

Authors:  Karla M Treitl; Alma Ali; Marcus Treitl
Journal:  Eur Radiol       Date:  2015-10-02       Impact factor: 5.315

7.  Usefulness and safety of the "God's Hand" pneumatic compression device for hemostasis in femoral catheterization.

Authors:  Sungwon Kim; Jae Hyun Kwon; Yoon Hee Han; Jeung Sook Kim
Journal:  Diagn Interv Radiol       Date:  2017 Jan-Feb       Impact factor: 2.630

8.  Comparison of Exo-Seal(®) and Angio-Seal (®) for arterial puncture site closure: A randomized, multicenter, single-blind trial.

Authors:  Johannes Ketterle; Harald Rittger; Inga Helmig; Lutz Klinghammer; Stefan Zimmermann; Wolfgang Hohenforst-Schmidt; Johannes Brachmann; Holger Nef; Stephan Achenbach; Christian Schlundt
Journal:  Herz       Date:  2015-06-13       Impact factor: 1.443

9.  [Arterial closure devices. What device for which clinical situation?].

Authors:  M Treitl; K M Eberhardt; D Maxien; B Behrends; M F Reiser
Journal:  Radiologe       Date:  2013-03       Impact factor: 0.635

10.  Vascular closure device failure in contemporary practice.

Authors:  Venkatesan D Vidi; Michael E Matheny; Usha S Govindarajulu; Sharon-Lise T Normand; Susan L Robbins; Vikram V Agarwal; Sripal Bangalore; Frederic S Resnic
Journal:  JACC Cardiovasc Interv       Date:  2012-08       Impact factor: 11.195

View more