Literature DB >> 20362295

Multi-residue analysis of pharmaceutical compounds in wastewaters by dual solid-phase microextraction coupled to liquid chromatography electrospray ionization ion trap mass spectrometry.

Nora Unceta1, M Carmen Sampedro, Nor Kartini Abu Bakar, Alberto Gómez-Caballero, M Aránzazu Goicolea, Ramón J Barrio.   

Abstract

The aim of this article is to present a new procedure based on dual solid-phase microextraction (dSPME) for the simultaneous extraction of 16 pharmaceutical compounds with acidic and basic characteristics in urban wastewaters. Water samples are divided into two aliquots of 2 mL each extracted by two CW-TPR fibers at different pH values (pH 3 and 11) and with a NaCl concentration of 300 g L(-1) at 75 degrees C for 30 min. The analytes in both fibers are desorbed one after the other in the desorption chamber in static mode with mobile phase for 10 min. The extracts are injected into an LC system coupled to an ion trap mass spectrometer, leading to the accurate quantification of 16 pharmaceutical compounds in wastewaters, in MS(2) mode. All the target compounds found in wastewaters provide good signals corresponding to the protonated precursor ion [M+H](+). The parameters influencing adsorption and desorption of the analytes on fiber were optimized. The assessment of the analytical method was performed by studying the linearity (LOQ to 10 ng mL(-1)) and the intra- and interday accuracy (89.2-109.7%) and precision (RSD <13.6%). The quantification limits obtained ranged between 0.005 and 0.05 microg L(-1). The application of the method to real samples proves its effectiveness in identifying and detecting naproxen, valsartan, bezafibrate, torasemide, diclofenac, carbamazepine, citalopram, lorazepan, fluoxetine, imipramine and amitriptyline in influent and effluent wastewater treatment plant samples. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20362295     DOI: 10.1016/j.chroma.2010.03.008

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Psychoactive drugs: occurrence in aquatic environment, analytical methods, and ecotoxicity-a review.

Authors:  Deivisson Lopes Cunha; Frederico Goytacazes de Araujo; Marcia Marques
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-23       Impact factor: 4.223

2.  Determination of the psychoactive drugs carbamazepine and diazepam in hospital effluent and identification of their metabolites.

Authors:  Carlos A A de Almeida; Maurício S Oliveira; Carlos A Mallmann; Ayrton F Martins
Journal:  Environ Sci Pollut Res Int       Date:  2015-07-03       Impact factor: 4.223

3.  Application of activated carbon-decorated polyacrylonitrile nanofibers as an adsorbent in dispersive solid-phase extraction of fluoroquinolones from wastewater.

Authors:  K Mogolodi Dimpe; Philiswa N Nomngongo
Journal:  J Pharm Anal       Date:  2019-01-10

4.  A gadolinium-based magnetic ionic liquid for dispersive liquid-liquid microextraction.

Authors:  Mohamed A Abdelaziz; Fotouh R Mansour; Neil D Danielson
Journal:  Anal Bioanal Chem       Date:  2020-10-23       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.