A new infusion sustainer that stabilizes perfusion during sutureless 25-gauge vitrectomy.

Takayuki Hattori1, Hiroyuki Shimada, Hiroyuki Nakashizuka, Ryusaburo Mori, Yoshihiro Mizutani, Mitsuko Yuzawa.   

Abstract

To stabilize perfusion during sutureless 25-gauge (25G) vitrectomy, we designed an infusion sustainer and examined its usefulness. A reusable infusion sustainer was constructed by soldering a piece of metal wire to a metal paper clip and curling the two ends of the wire. For use, the sustainer was clipped onto the lip retractor, and the infusion line and chandelier fiber were passed through the wire loops. 25G vitrectomy was conducted in three porcine eyes, with insertion of a tonometer to monitor intraocular pressure (IOP). The relation between infusion port direction and IOP was examined. In a clinical study, 30 eyes that underwent 25G vitrectomy using the infusion sustainer and 30 eyes without using the infusion sustainer were compared for IOP maintenance and complications. In the porcine eye, after angled incision, the infusion tip was pointing toward the basal vitreous on the anterior side of the eyeball. Under these conditions, vitreous resection was accompanied by IOP lowering. When the infusion tip was moved so as to be directed toward the central vitreous, IOP was maintained. In the clinical study, among the eyes undergoing vitrectomy without the infusion sustainer, IOP decreased during operation in 30 eyes, and infusion fluid or air flowed into the anterior chamber in four eyes. In the 30 eyes in which the sustainer was used, no IOP lowering and no infusion fluid or air flow into the anterior chamber were detected, due to stabilization of the infusion port. Use of the infusion sustainer orients the infusion port toward the central vitreous, stabilizes IOP and prevents flow of infusion fluid or air into the anterior chamber. This infusion sustainer is useful to perform sutureless 25G vitrectomy safely.

Mesh:

Year:  2010        PMID: 20361231     DOI: 10.1007/s10792-010-9365-0

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  8 in total

1.  Expanded indications for 25-gauge transconjunctival vitrectomy.

Authors:  Hiroyuki Shimada; Hiroyuki Nakashizuka; Ryuzaburo Mori; Yoshihiro Mizutani
Journal:  Jpn J Ophthalmol       Date:  2005 Sep-Oct       Impact factor: 2.447

2.  Problems associated with the 25-gauge transconjunctival sutureless vitrectomy system during and after surgery.

Authors:  Suk Ho Byeon; Young Kwang Chu; Sung Chul Lee; Hyoung Jun Koh; Sung Soo Kim; Oh Woong Kwon
Journal:  Ophthalmologica       Date:  2006       Impact factor: 3.250

3.  25-gauge scleral tunnel transconjunctival vitrectomy.

Authors:  Hiroyuki Shimada; Hiroyuki Nakashizuka; Ryuzaburo Mori; Yoshihiro Mizutani; Takayuki Hattori
Journal:  Am J Ophthalmol       Date:  2006-11       Impact factor: 5.258

4.  Visual recovery after vitrectomy for macular hole using 25-gauge instruments.

Authors:  Hajime Shinoda; Kei Shinoda; Shingo Satofuka; Yutaka Imamura; Yoko Ozawa; Susumu Ishida; Makoto Inoue
Journal:  Acta Ophthalmol       Date:  2007-08-28       Impact factor: 3.761

5.  Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery.

Authors:  Gildo Y Fujii; Eugene De Juan; Mark S Humayun; Tom S Chang; Dante J Pieramici; Aaron Barnes; David Kent
Journal:  Ophthalmology       Date:  2002-10       Impact factor: 12.079

6.  Fluid dynamics in three 25-gauge vitrectomy systems: principles for use in vitreoretinal surgery.

Authors:  Octaviano Magalhães; Maurício Maia; André Maia; Fernando Penha; Eduardo Dib; Michel Eid Farah; Paulo Schor
Journal:  Acta Ophthalmol       Date:  2008-03       Impact factor: 3.761

7.  Vitreous dynamics: vitreous flow analysis in 20-, 23-, and 25-gauge cutters.

Authors:  Octaviano Magalhaes; Lawrence Chong; Charles DeBoer; Prashant Bhadri; Ralph Kerns; Aaron Barnes; Sophia Fang; Mark Humayun
Journal:  Retina       Date:  2008-02       Impact factor: 4.256

8.  Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy.

Authors:  F Okamoto; C Okamoto; N Sakata; K Hiratsuka; N Yamane; T Hiraoka; Y Kaji; T Oshika
Journal:  Ophthalmology       Date:  2007-12       Impact factor: 12.079