Literature DB >> 20358110

Diffusive spreading of time-dependent pressures in elastic microfluidic devices.

Bernhard K Wunderlich1, Ulrich A Klessinger, Andreas R Bausch.   

Abstract

Here we show that transient flow of Newtonian fluids in viscoelastic PDMS microfluidic channels can be described by a diffusive pressure spreading mechanism analogous to the electric telegrapher's equation. The pressure diffusion constant D(p) = 1/R(x)C(x) of a channel with length l is determined by the hydrodynamic resistance R(x) and capacitance C(x) per unit length of the channel. l(2)/D(p) sets the timescale for the transmission of pressure steps along the channel and the relaxation after a pressure step in steady state flow. For oscillatory flows, the channel acts as a low-pass filter with a cutoff frequency omega(cutoff) = 2piD(p)l(-2), so that pressure and flow rate pulses disperse and get smoothed while they travel along the channel. The combination of different microparticle tracking techniques allows the determination of pressure and flow profiles at any point in the channel and excellent agreement with theoretical predictions is obtained.

Mesh:

Substances:

Year:  2010        PMID: 20358110     DOI: 10.1039/b920221h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  1 in total

1.  Microfluidic system for generation of sinusoidal glucose waveforms for entrainment of islets of Langerhans.

Authors:  Xinyu Zhang; Alix Grimley; Richard Bertram; Michael G Roper
Journal:  Anal Chem       Date:  2010-08-01       Impact factor: 6.986

  1 in total