Literature DB >> 20357694

Effect of subcutaneous fat on quantitative bone ultrasound in chicken and neonates.

Monika Bajaj1, Winston Koo, Mouhanad Hammami, Elaine M Hockman.   

Abstract

Bone quantitative ultrasound generated speed of sound (SOS) is a marker of bone strength. However, critical evaluation of its validity for use in small bones is extremely limited, and SOS data may not be consistent with data obtained from dual energy x ray absorptiometry, another marker of bone strength. We report the SOS values pre and postinjection of s.c. fat using a chicken bone model; and in large for gestation and appropriate for gestation neonates to determine the influence of s.c. fat. Average SOS were lowered for the chicken bones postfat injection by 36 m/s (CS probe) and 58 m/s (CR probe), and in large for gestation group by 75 m/s (CS probe) and 51 m/s (CR probe) (p = 0.03-0.004 paired t test) although SOS measurements from each probe are significantly correlated within the large (r = 0.78) and appropriate (r = 0.83) for gestation group. Failed SOS measurements occurred significantly more frequently in the postinjection studies regardless of the probe used in the chicken bone model and for the CS probe in large for gestation neonates. The lowered bone quantitative ultrasound measurements in large for gestation neonates is likely a measurement artifact from increased s.c. fat.

Entities:  

Mesh:

Year:  2010        PMID: 20357694     DOI: 10.1203/PDR.0b013e3181df9c8c

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  4 in total

1.  Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation.

Authors:  Eenas A Omari; Tomy Varghese; Ernest L Madsen; Gary Frank
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

2.  Theoretical and phantom based investigation of the impact of sound speed and backscatter variations on attenuation slope estimation.

Authors:  Eenas Omari; Heichang Lee; Tomy Varghese
Journal:  Ultrasonics       Date:  2011-03-23       Impact factor: 2.890

3.  Brazilian pediatric reference data for quantitative ultrasound of phalanges according to gender, age, height and weight.

Authors:  Ezequiel Moreira Gonçalves; Roberto Regis Ribeiro; Wellington Roberto Gomes de Carvalho; Anderson Marques de Moraes; Everton Paulo Roman; Keila Donassolo Santos; Pedro Augusto Rodrigues Medaets; Nélio Neves Veiga-Junior; Adrielle Caroline Lace de Moraes Coelho; Tathyane Krahenbühl; Leticia Esposito Sewaybricker; Antonio de Azevedo Barros-Filho; Andre Moreno Morcillo; Gil Guerra-Júnior
Journal:  PLoS One       Date:  2015-06-04       Impact factor: 3.240

4.  Is quantitative ultrasound a measure for metabolic bone disease in preterm-born infants? A prospective subcohort study.

Authors:  A de Lange; J M Maaskant; M M van Weissenbruch
Journal:  Eur J Pediatr       Date:  2021-04-22       Impact factor: 3.183

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.