Percutaneous closure of hypertensive ductus arteriosus.

Carlos Zabal1, José Antonio García-Montes, Alfonso Buendía-Hernández, Juan Calderón-Colmenero, Emilia Patiño-Bahena, Antonio Juanico-Enriquez, Fause Attie.   

Abstract

BACKGROUND: The Amplatzer duct occluder (ADO) has been used with success to close large patent ductus arteriosus (PDA), but some problems exist especially with hypertensive PDAs, such as incomplete closure, haemolysis, left pulmonary artery stenosis, obstruction of the descending aorta and progressive pulmonary vascular disease. METHODS AND
RESULTS: We analysed a group of 168 patients with isolated PDA and pulmonary artery systolic pressure (PSAP) > or =50 mm Hg. Mean age was 10.3 +/- 14.3 years (median 3.9), PDA diameter was 6.4 +/- 2.9 mm (median 5.9), PASP was 63.5 +/- 16.2 mm Hg (median 60), Qp/Qs was 2.7 +/- 1.2 (median 2.5), total pulmonary resistance index (PRI) was 3.69 +/- 2.15 (median 3.35) and vascular PRI was 2.73 +/- 1.72 (median 2.37). We used ADOs in 145 (86.3%) cases, Amplatzer muscular ventricular septal defect occluders (AMVSDO) in 18 (10.7%), Amplatzer septal occluders (ASO) in three (1.8%) and the Gianturco-Grifka device in two (1.2%) cases. Device diameter was 106.3% +/- 51% higher than PDA diameter. PASP decreased after occlusion to 42.5 +/- 13.3 mm Hg (p<0.00001). Immediately after closure, no or trivial shunt was present in 123 (74.5%) cases. Immediate complications were device embolisation in five (3%) cases and descending aortic obstruction in one case. The overall success rate was 98.2%. Follow-up in 145 (86.3%) cases for 37.1 +/- 24 months (median 34.1) showed further decrease of the PASP to 30.1 +/- 7.7 mm Hg (p<0.0001).
CONCLUSIONS: Percutaneous treatment of hypertensive PDA is safe and effective. ADO works well for most cases, but sometimes other devices (MVSDO or ASO) have to be used. When cases are selected adequately, pulmonary pressures decrease immediately and continue to fall with time.

Entities:  

Mesh:

Year:  2010        PMID: 20357390     DOI: 10.1136/hrt.2009.185025

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  6 in total

1.  Safety and Outcomes of Transcatheter Closure of Patent Ductus Arteriosus in Children With Pulmonary Artery Hypertension.

Authors:  Arash Salavitabar; Usha S Krishnan; Mariel E Turner; Julie A Vincent; Alejandro J Torres; Matthew A Crystal
Journal:  Tex Heart Inst J       Date:  2020-08-01

2.  Safety and Efficacy of the Nit-Occlud® Coil for Percutaneous Closure of Various Sizes of PDA.

Authors:  Seyong Jung; Jaehee Seol; Jaeyoung Choi; Keesoo Ha
Journal:  J Clin Med       Date:  2022-04-28       Impact factor: 4.964

Review 3.  Severe spinal cord ischemic injury secondary to device embolization after transcatheter closure of a patent arterial duct.

Authors:  Liang Tang; Shenghua Zhou; Xiangqian Shen
Journal:  Tex Heart Inst J       Date:  2014-02

Review 4.  Recent advances in pediatric interventional cardiology.

Authors:  Seong-Ho Kim
Journal:  Korean J Pediatr       Date:  2017-08-14

5.  Long-Term Results of Transcatheter Closure of Large Patent Ductus Arteriosus with Severe Pulmonary Arterial Hypertension in Pediatric Patients.

Authors:  Jayal Hasmukhbhai Shah; Dharmin Khimjibhai Bhalodiya; Abhishek Pravinchandra Rawal; Tushar Sudhakarrao Nikam
Journal:  Int J Appl Basic Med Res       Date:  2020-01-03

6.  Percutaneous closure of patent arterial ducts in patients from high altitude: a sub-Saharan experience.

Authors:  Endale Tefera; Shakeel A Qureshi; Ramòn Bermudez-Cañete; Lola Rubio
Journal:  Ann Pediatr Cardiol       Date:  2015 Sep-Dec
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.