Literature DB >> 20355966

Fabrication and testing of a microneedles sensor array for p-cresol detection with potential biofuel applications.

Jason C Harper1, Susan M Brozik, Jeb H Flemming, Jaime L McClain, Ronen Polsky, Dominic Raj, Gregory A Ten Eyck, David R Wheeler, Komandoor E Achyuthan.   

Abstract

We present a miniaturized high-throughput sensor array that will augment biofuel technology by facilitating in situ biochemical measurements upon micrometer-scale surfaces of leaves, stems, or petals. We used semiconductor processing to photopattern Foturan glass wafers and fabricated gold-plated microscopic electrode needles (ElectroNeedles) that pierced 125-mum-thick surfaces without deformation. The 5 x 5 or 10 x 10 arrays of ElectroNeedles can analyze 25 or 100 samples simultaneously, increasing throughput. Each microneedle in the array can also be individually addressed and selectively functionalized using diazonium electrodeposition, conferring multiplexing capability. Our microfabrication is a simple, inexpensive, and rapid alternative to the time-, cost-, and protocol-intense, deep-reactive-ion-etching Bosch process. We validated the system performance by electrochemically detecting p-cresol, a phenolic substrate for laccase, an enzyme that is implicated in lignin degradation and therefore important to biofuels. Our limits of detection (LOD) and quantization (LOQ) for p-cresol were 1.8 and 16microM, respectively, rivaling fluorescence detection (LOD and LOQ = 0.4 and 3microM, respectively). ElectroNeedles are multiplexed, high-throughput, chip-based sensor arrays designed for minimally invasive penetration of plant surfaces, enabling in situ and point-of-test analyses of biofuel-related biochemicals.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20355966     DOI: 10.1021/am900259u

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  5 in total

1.  Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array.

Authors:  Somasekhar R Chinnadayyala; Ilhwan Park; Sungbo Cho
Journal:  Mikrochim Acta       Date:  2018-04-07       Impact factor: 5.833

Review 2.  Microneedles for drug and vaccine delivery.

Authors:  Yeu-Chun Kim; Jung-Hwan Park; Mark R Prausnitz
Journal:  Adv Drug Deliv Rev       Date:  2012-05-01       Impact factor: 15.470

3.  Hitherto unrecognized fluorescence properties of coniferyl alcohol.

Authors:  Komandoor Elayavalli Achyuthan; Paul David Adams; Supratim Datta; Blake Alexander Simmons; Anup Kumar Singh
Journal:  Molecules       Date:  2010-03-11       Impact factor: 4.411

4.  Spectroscopic analyses of the biofuels-critical phytochemical coniferyl alcohol and its enzyme-catalyzed oxidation products.

Authors:  Komandoor Elayavalli Achyuthan; Paul David Adams; Blake Alexander Simmons; Anup Kumar Singh
Journal:  Molecules       Date:  2009-11-23       Impact factor: 4.411

Review 5.  Miniaturization and 3D Printing of Bioreactors: A Technological Mini Review.

Authors:  Spyridon Achinas; Jorn-Ids Heins; Janneke Krooneman; Gerrit Jan Willem Euverink
Journal:  Micromachines (Basel)       Date:  2020-09-14       Impact factor: 2.891

  5 in total