Literature DB >> 20355762

Novel thrombo-resistant coating based on iron-polysaccharide complex multilayers.

Meng Liu1, Xiuli Yue, Zhifei Dai, Yan Ma, Lei Xing, Zhengbao Zha, Shaoqin Liu, Yu Li.   

Abstract

The biocompatibility of iron-polysaccharide complexes has been well-documented. Herein, a stable thrombo-resistant coating was fabricated by consecutive adsorption of Fe (III) and polysaccharides including heparin (Hep) and dextran sulfate (DS) onto various surface by layer-by-layer self-assembly technique via both electrostatic interaction and chemical complexation process. The absorbance at 350 nm increased linearly with the number of Fe3+/Hep multilayer, indicating the formation of multilayer structure and the uniform coating. Compared with (Fe3+/Hep)10, the (Fe3+/DS/Fe3+/Hep)5 coating was more hydrophilic and stable due to the incorporation of DS. The activated partial thromboplastin time (APTT) and platelet adhesion assays showed that both (Fe3+/Hep)10 and (Fe3+/DS/Fe3+/Hep)5 coated surfaces were anticoagulant. The complexing with ferric ions did not compromise the catalytic capacity of heparin to promote antithrombin(III)-mediated thrombin inactivation. Chromogenic assays for heparin activity proved definitively that the inhibition of locally produced thrombin was contributed to the thromboresistance of the surface-bound heparin. The surface with Hep or DS as the outmost layer showed stronger anticoagulant activity than Fe3+, indicating that the outermost layer of the coating played a key role in anticoagulant activity. The utilization of dextran sulfate/heparin surfaces was more advantageous than merely the heparin surface for improving blood-contacting medical devices for long-term usage.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20355762     DOI: 10.1021/am800042v

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  5 in total

1.  In-Vitro Endothelialization Assessment of Heparinized Bovine Pericardial Scaffold for Cardiovascular Application.

Authors:  My Thi Ngoc Nguyen; Ha Le Bao Tran
Journal:  Polymers (Basel)       Date:  2022-05-26       Impact factor: 4.967

2.  Surface modification of polysulfone based hemodialysis membranes with layer by layer self assembly of polyethyleneimine/alginate-heparin: a simple polyelectrolyte blend approach for heparin immobilization.

Authors:  Filiz Yasar Mahlicli; Sacide Alsoy Altinkaya
Journal:  J Mater Sci Mater Med       Date:  2013-02       Impact factor: 3.896

Review 3.  Multivalent Ions as Reactive Crosslinkers for Biopolymers-A Review.

Authors:  Florian Wurm; Barbara Rietzler; Tung Pham; Thomas Bechtold
Journal:  Molecules       Date:  2020-04-16       Impact factor: 4.411

4.  Pumpkin Skin Polysaccharide-Zn(II) Complex: Preparation, Characterization, and Suppression of Inflammation in Zebrafish.

Authors:  Shujun Dong; Bin Zhang; Yue Ma; Hong Chang; Zhenjia Zheng; Xiaoyan Zhao
Journal:  Foods       Date:  2022-08-28

5.  Heparin nanomodification improves biocompatibility and biomechanical stability of decellularized vascular scaffolds.

Authors:  Yunming Tao; Tiehui Hu; Zhongshi Wu; Hao Tang; Yerong Hu; Qi Tan; Chunlin Wu
Journal:  Int J Nanomedicine       Date:  2012-11-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.