Seal properties of TachoSil: in vitro hemodynamic measurements.

Denis Berdajs1, Marco Bürki, Alexandre Michelis, Ludwig K von Segesser.   

Abstract

Fibrin glue products and collagen patches are frequently used as a sealing product, preventing surgical side bleedings. This is especially true in the field of cardiovascular surgery, where increasing numbers of patients are being operated with antiplatelet and anticoagulation therapy. The aim of this report was, in an in vitro hemodynamic setting, to examine the sealant properties of the TachoSil (Nycomed Pharma, Linz, Austria) patch. Burst pressure and normal force of 15 TachoSil sealed defects were measured. This was determined in a closed hydraulic system. Mean burst pressure load for a 5-mm defect was 69+/-11.4 mmHg; for a 7-mm defect was 63+/-16 mmHg; and, 62+/-16 mmHg for the defect with a diameter of 10 mm (P>0.05). The mean calculated normal force was as follows: 0.91+/-0.15 N for the 5 mm defect, 6.5+/-1.6 N for the 7 mm, and 8.1+/-0.75 N for the 10 mm defect. The TachoSil patch has the capability to seal small defects. However, at the larger defects the seal character was significantly reduced. These results suggest that the device may be a good alternative for hemostasis for small defects. The capacity to curtail or stop hemorrhage at the larger defects is unlikely.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20354036     DOI: 10.1510/icvts.2010.235127

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  4 in total

Review 1.  Comparison of hemostatic agents used in vascular surgery.

Authors:  Krishna S Vyas; Sibu P Saha
Journal:  Expert Opin Biol Ther       Date:  2013-10-22       Impact factor: 4.388

2.  Myocardial infarction-related left ventricular rupture with the tear across the ventricular wall detected on echocardiography.

Authors:  Masaki Yamamoto; Tadashi Isomura; Kazumasa Orihashi; Kohei Miyashita; Hiroaki Kitaoka; Kazuhiro Hanazaki; Naohito Yamasaki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-10-17

Review 3.  Topical biomaterials to prevent post-tonsillectomy hemorrhage.

Authors:  Lumei Liu; Cole Rodman; Noah E Worobetz; Jed Johnson; Charles Elmaraghy; Tendy Chiang
Journal:  J Otolaryngol Head Neck Surg       Date:  2019-09-06

4.  Ex vivo evaluation of a multilayered sealant patch for watertight dural closure: cranial and spinal models.

Authors:  A Kinaci; S van Thoor; S Redegeld; M Tooren; T P C van Doormaal
Journal:  J Mater Sci Mater Med       Date:  2021-07-23       Impact factor: 4.727

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.