Literature DB >> 20353738

Body fluid volume and nutritional status in hemodialysis: vector bioelectric impedance analysis.

M A Espinosa Cuevas1, G Navarrete Rodriguez, M E Villeda Martinez, X Atilano Carsi, P Miranda Alatriste, T Tostado Gutiérrez, R Correa-Rotter.   

Abstract

BACKGROUND: Protein-energy malnutrition and hypervolemia are major causes of morbidity and mortality in patients on chronic hemodialysis (CHD). The methods used to evaluate nutritional status and volume status remain controversial. Vector bioelectric impedance analysis (vector- BIA) has recently been developed to assess both nutritional status and tissue hydration. The purpose of the study was to assess the nutritional status and volume status of patients on CHD with conventional nutritional assessment methods and with vector-BIA and then to compare the resulting findings.
METHODS: 76 Mexican patients on CHD were studied. Nutritional status and body composition were assessed with anthropometry, biochemical variables, and the modified Bilbrey nutritional index (mBNI), the results were compared with both conventional BIA and vector-BIA.
RESULTS: The BNI was used to determine the number of patients with normal nutritional status (n = 27, 35.5%), and mild (n = 31, 40.8%), moderate (n = 10, 13.2%) and severe malnutrition (n = 8, 10.5%). Patients displayed shorter vectors with smaller phase angles or with an overhydration vectorial pattern before the initiation of their hemodialysis session. There was general improvement to normal hydration status post-dialysis (p < 0.05); however, 28% remained overhydrated as assessed by vector-BIA. The vector-BIA results showed that worse malnutrition status was associated with greater volume overload (p < 0.05). Diabetes mellitus (DM) was associated with shorter vectors with smaller phase angles (a vectorial pattern of overhydration and cachexia) (p < 0.05). Patients with lower serum creatinine presented with shorter vectors and smaller phase angles (vectorial patterns of malnutrition and/or overhydration) (p < 0.05). In women, lower serum albumin (< 3.4 g/dl) correlated with greater overhydration and malnutrition (p < 0.05).
CONCLUSIONS: In this population, the vector-BIA showed that 28% of the population remained overhydrated after their hemodialysis session. Diabetics and those with moderate or severe malnutrition were more overhydrated, which is a condition that may be associated with increased cardiovascular morbidity. Because nutritional and volume status are important factors associated with morbidity and mortality in CHD patients, we focused on optimizing the use of existing methods. Our studies suggest that vector-BIA offers a comprehensive and reliable reproducible means of assessing both volume and masses at the bedside and can complement the traditional methods.

Entities:  

Mesh:

Year:  2010        PMID: 20353738

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975


  6 in total

1.  Comparison of Bioelectrical Impedance Vector Analysis (BIVA) to 7-point Subjective Global Assessment for the diagnosis of malnutrition.

Authors:  Clara S A Sugizaki; Nayara P Queiroz; Débora M Silva; Ana T V S Freitas; Nara A Costa; Maria R G Peixoto
Journal:  J Bras Nefrol       Date:  2022 Apr-Jun

2.  Bioelectric Impedance Analysis in the Diagnosis of Vesicoureteral Reflux.

Authors:  Meral Torun Bayram; Demet Alaygut; Mehmet Turkmen; Alper Soylu; Salih Kavukcu
Journal:  Iran J Pediatr       Date:  2015-08-24       Impact factor: 0.364

3.  Relationship between protein-energy wasting in adults with chronic hemodialysis and the response to treatment with erythropoietin.

Authors:  Ailema González-Ortiz; Ricardo Correa-Rotter; Armando Vázquez-Rangel; Olynka Vega-Vega; Ángeles Espinosa-Cuevas
Journal:  BMC Nephrol       Date:  2019-08-14       Impact factor: 2.388

4.  Influence of dry weight reduction on anemia in patients undergoing hemodialysis.

Authors:  Yinghui Deng; Hua Liu; Na Lin; Lina Ma; Wenjing Fu
Journal:  J Int Med Res       Date:  2019-09-17       Impact factor: 1.671

5.  High-sensitivity troponins in dialysis patients: variation and prognostic value.

Authors:  Sunna Snaedal; Peter Bárány; Sigrún H Lund; Abdul R Qureshi; Olof Heimbürger; Peter Stenvinkel; Christian Löwbeer; Karolina Szummer
Journal:  Clin Kidney J       Date:  2020-12-12

6.  Glucose-independent segmental phase angles from multi-frequency bioimpedance analysis to discriminate diabetes mellitus.

Authors:  Min-Ho Jun; Soochan Kim; Boncho Ku; JungHee Cho; Kahye Kim; Ho-Ryong Yoo; Jaeuk U Kim
Journal:  Sci Rep       Date:  2018-01-12       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.