Literature DB >> 20352280

Freehand liver volumetry by using an electromagnetic pen tablet: accuracy, precision, and rapidity.

Simone Perandini1, Niccolò Faccioli, Marco Inama, Roberto Pozzi Mucelli.   

Abstract

The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy and precision testing were computed by software developed in our institution. This computer software can generate models of solid organs and allows both standard mouse-based and electromagnetic pen-driven segmentation (number of data sets, n = 70). The images used as input for rapidity testing was partly computed by modeling software (n = 70) and partly selected from contrast-enhanced computed tomography (CT) examinations (n = 12). Mean volumes and time required to perform the segmentation, along with standard deviation and range values with both techniques, were calculated. Student's t test was used to assess significance regarding mean volumes and time calculated by using both segmentation techniques on phantom and CT data sets. P value was also calculated. The mean volume difference was significantly lower with the use of the freehand electromagnetic pen as compared with the optical mouse (0.2% vs. 1.8%; P < .001). The mean segmentation time per patient was significantly shorter with the use of the freehand electromagnetic pen contourtracing method (354.5 vs. 499.1 s on phantoms; 457.4 vs. 610.0 s on CT images; P < .001). Freehand electromagnetic pen-based volumetric technique represents a technologic advancement over manual mouse-based contourtracing because of the superior statistical accuracy and sensibly shorter time required. Further studies focused on intra- and interobserver variability of the technique need to be performed before its introduction in clinical application.

Entities:  

Mesh:

Year:  2011        PMID: 20352280      PMCID: PMC3056975          DOI: 10.1007/s10278-010-9291-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  14 in total

Review 1.  Use of imaging for living donor liver transplantation.

Authors:  M J Bassignani; A S Fulcher; R A Szucs; W K Chong; U R Prasad; A Marcos
Journal:  Radiographics       Date:  2001 Jan-Feb       Impact factor: 5.333

2.  Comparison of two volumetric techniques for estimating liver volume using magnetic resonance imaging.

Authors:  Michael Mazonakis; John Damilakis; Thomas Maris; Panos Prassopoulos; Nicholas Gourtsoyiannis
Journal:  J Magn Reson Imaging       Date:  2002-05       Impact factor: 4.813

3.  Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging.

Authors:  J Bakker; M Olree; R Kaatee; E E de Lange; K G Moons; J J Beutler; F J Beek
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

4.  Accuracy and significance of pretransplant liver volume measured by magnetic resonance imaging.

Authors:  S H Caldwell; E E de Lange; M J Gaffey; M Sue; J C Boyd; R C Dickson; C Driscoll; W C Stevenson; M B Ishitani; C McCullough; T L Pruett
Journal:  Liver Transpl Surg       Date:  1996-11

5.  Liver and spleen volumetry with quantitative MR imaging and dual-space clustering segmentation.

Authors:  Steven W Farraher; Hernan Jara; Kevin J Chang; Andrew Hou; Jorge A Soto
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

6.  Automated segmentation of the liver from 3D CT images using probabilistic atlas and multilevel statistical shape model.

Authors:  Toshiyuki Okada; Ryuji Shimada; Masatoshi Hori; Masahiko Nakamoto; Yen-Wei Chen; Hironobu Nakamura; Yoshinobu Sato
Journal:  Acad Radiol       Date:  2008-11       Impact factor: 3.173

7.  Liver regeneration at day 7 after right hepatectomy: global and segmental volumetric analysis by using CT.

Authors:  Magaly Zappa; Federica Dondero; Annie Sibert; Marie-Pierre Vullierme; Jacques Belghiti; Valerie Vilgrain
Journal:  Radiology       Date:  2009-08       Impact factor: 11.105

8.  Reliability and exactness of MRI-based volumetry: a phantom study.

Authors:  A R Luft; M Skalej; D Welte; R Kolb; U Klose
Journal:  J Magn Reson Imaging       Date:  1996 Jul-Aug       Impact factor: 4.813

9.  Preoperative measurement of segmental liver volume of donors for living related liver transplantation.

Authors:  S Kawasaki; M Makuuchi; H Matsunami; Y Hashikura; T Ikegami; H Chisuwa; T Ikeno; T Noike; T Takayama; H Kawarazaki
Journal:  Hepatology       Date:  1993-11       Impact factor: 17.425

10.  Volumetric analysis of liver segments in 155 living donors.

Authors:  Surasak Leelaudomlipi; Yasuhiko Sugawara; Junichi Kaneko; Yuichi Matsui; Takao Ohkubo; Masatoshi Makuuchi
Journal:  Liver Transpl       Date:  2002-07       Impact factor: 5.799

View more
  1 in total

1.  Pregnancy and weaning regulate human maternal liver size and function.

Authors:  Alexandra Q Bartlett; Kimberly K Vesco; Jonathan Q Purnell; Melanie Francisco; Erica Goddard; Xiangnan Guan; Andrea DeBarber; Michael C Leo; Eric Baetscher; William Rooney; Willscott Naugler; Alexander R Guimaraes; Patrick Catalano; Zheng Xia; Pepper Schedin
Journal:  Proc Natl Acad Sci U S A       Date:  2021-11-30       Impact factor: 11.205

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.