Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector.

Philip M Evans1, J Richard N Symonds-Tayler, Ruth Colgan, Geoffrey D Hugo, Nicky Letts, Carlos Sandin.   

Abstract

The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness and symmetry characteristics and duty cycle for a range of beam-on times and gating periods. Results were compared with a standard ungated delivery as a reference. For all beam-on times, down to 0.5 s, dosimetric differences were below +/-1% and flatness and symmetry parameter variations were below +/-1.5%. For the shorter beam-on times the in-house detector deviated from the other two detectors, suggesting that this device should be used in conjunction with other detectors for absolute dosimetry purposes. However, it was found to be useful for studying gated beam characteristics pulse by pulse.

Entities:  

Mesh:

Year:  2010        PMID: 20348610     DOI: 10.1088/0031-9155/55/8/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

Authors:  Brendan Whelan; Lois Holloway; Dragos Constantin; Brad Oborn; Magdalena Bazalova-Carter; Rebecca Fahrig; Paul Keall
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

2.  Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac.

Authors:  Philipp Freislederer; Michael Reiner; Winfried Hoischen; Anton Quanz; Christian Heinz; Franziska Walter; Claus Belka; Matthias Soehn
Journal:  Radiat Oncol       Date:  2015-03-19       Impact factor: 3.481

3.  Does gated beam delivery impact delivery accuracy on an Elekta linac?

Authors:  Mohammed Jermoumi; Roger Xie; Daliang Cao; David J Housley; David M Shepard
Journal:  J Appl Clin Med Phys       Date:  2017-01-03       Impact factor: 2.102

4.  Low-cost Kinect Version 2 imaging system for breath hold monitoring and gating: Proof of concept study for breast cancer VMAT radiotherapy.

Authors:  David M Edmunds; Lone Gothard; Komel Khabra; Anna Kirby; Poonam Madhale; Helen McNair; David Roberts; K K Tang; Richard Symonds-Tayler; Fatemeh Tahavori; Kevin Wells; Ellen Donovan
Journal:  J Appl Clin Med Phys       Date:  2018-03-13       Impact factor: 2.102

5.  Delivery efficiency of an Elekta linac under gated operation.

Authors:  Guoqiang Cui; David J Housley; Fan Chen; Vivek K Mehta; David M Shepard
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

6.  Accuracy of real-time respiratory motion tracking and time delay of gating radiotherapy based on optical surface imaging technique.

Authors:  Li Chen; Sen Bai; Guangjun Li; Zhibin Li; Qing Xiao; Long Bai; Changhu Li; Lixun Xian; Zhenyao Hu; Guyu Dai; Guangyu Wang
Journal:  Radiat Oncol       Date:  2020-07-10       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.