Dosimetric evaluation of inspiration and expiration breath-hold for intensity-modulated radiotherapy planning of non-small cell lung cancer.

Bilal A Tahir1, Christopher M Bragg, Sarah E Lawless, Matthew Q F Hatton, Rob H Ireland.   

Abstract

The purpose of this study was to compare target coverage and lung tissue sparing between inspiration and expiration breath-hold intensity-modulated radiotherapy (IMRT) plans for patients with non-small cell lung cancer (NSCLC). In a prospective study, seven NSCLC patients gave written consent to undergo both moderate deep inspiration and end-expiration breath-hold computed tomography (CT), which were used to generate five-field IMRT plans. Dose was calculated with a scatter and an inhomogeneity correction algorithm. The percentage of the planning target volume (PTV) receiving 90% of the prescription dose (PTV(90)), the volume of total lung receiving >or=10 Gy (V(10)) and >or=20 Gy (V(20)) and the mean lung dose (MLD) were compared by the Student's paired t-test. Compared with the expiration plans, the mean +/- SD reductions for V(10), V(20) and MLD on the inspiration plans were 4.0 +/- 3.7% (p = 0.031), 2.5 +/- 2.3% (p = 0.028) and 1.1 +/- 0.7 Gy (p = 0.007), respectively. Conversely, a mean difference of 1.1 +/- 1.1% (p = 0.044) in PTV(90) was demonstrated in favour of expiration. When using IMRT, inspiration breath-hold can reduce the dose to normal lung tissue while expiration breath-hold can improve the target coverage. The improved lung sparing at inspiration may outweigh the modest improvements in target coverage at expiration.

Entities:  

Mesh:

Year:  2010        PMID: 20348604     DOI: 10.1088/0031-9155/55/8/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients.

Authors:  Anna Simeonova-Chergou; Anika Jahnke; Kerstin Siebenlist; Florian Stieler; Sabine Mai; Judit Boda-Heggemann; Frederik Wenz; Frank Lohr; Lennart Jahnke
Journal:  Strahlenther Onkol       Date:  2016-01-15       Impact factor: 3.621

2.  Establishing a framework to implement 4D XCAT phantom for 4D radiotherapy research.

Authors:  Raj K Panta; Paul Segars; Fang-Fang Yin; Jing Cai
Journal:  J Cancer Res Ther       Date:  2012 Oct-Dec       Impact factor: 1.805

3.  Comparison of CT images with average intensity projection, free breathing, and mid-ventilation for dose calculation in lung cancer.

Authors:  Chirasak Khamfongkhruea; Sangutid Thongsawad; Chirapha Tannanonta; Sasikarn Chamchod
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.