Literature DB >> 20346646

Evaluation of a thermoplastic immobilization system for breast and chest wall radiation therapy.

Jared H Strydhorst1, Jean-Michel Caudrelier, Brenda G Clark, Lynn A Montgomery, Greg Fox, Miller S MacPherson.   

Abstract

We report on the impact of a thermoplastic immobilization system on intra- and interfraction motion for patients undergoing breast or chest wall radiation therapy. Patients for this study were treated using helical tomotherapy. All patients were immobilized using a thermoplastic shell extending from the shoulders to the ribcage. Intrafraction motion was assessed by measuring maximum displacement of the skin, heart, and chest wall on a pretreatment 4D computed tomography, while inter-fraction motion was inferred from patient shift data arising from daily image guidance procedures on tomotherapy. Using thermoplastic immobilization, the average maximum motion of the external contour was 1.3 ± 1.6 mm, whereas the chest wall was found to be 1.6 ± 1.9 mm. The day-to-day setup variation was found to be large, with random errors of 4.0, 12.0, and 4.5 mm in the left-right, superior-inferior, and anterior-posterior directions, respectively, and the standard deviations of the systematic errors were found to be 2.7, 9.8, and 4.1 mm. These errors would be expected to dominate any respiratory motion but can be mitigated by daily online image guidance. Using thermoplastic immobilization can effectively reduce respiratory motion of the chest wall and external contour, but these gains can only be realized if daily image guidance is used.
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20346646     DOI: 10.1016/j.meddos.2010.01.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy.

Authors:  Jidan Zhou; Shuai Li; Chengwei Ye; Konglong Shen; An Li; Gang Chen; Xiaoyu Li; Sen Bai; Weifeng Wang; Renming Zhong
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

2.  Comparing Accuracy of Thermoplastic Mask versus Commercial Bra for the Immobilization of Pendulous Breast During Radiation Therapy Treatment: A Retrospective Cohort Study.

Authors:  Zaheeda Mulla; Omar Iskanderani; Amina Weber; Abdullah AlMohamad; Mohammed Sheikh Al-Amoodi; Shamel Soaida
Journal:  Adv Radiat Oncol       Date:  2020-10-14

3.  Development of a novel airbag system of abdominal compression for reducing respiratory motion: preliminary results in healthy volunteers.

Authors:  Wenxin Li; Kenta Konishi; Keiichi Ohira; Masanori Hirata; Kohei Wakabayashi; Shuhei Aramaki; Masataka Sakamoto; Katsumasa Nakamura
Journal:  J Radiat Res       Date:  2022-07-19       Impact factor: 2.438

4.  Correlation between target motion and the dosimetric variance of breast and organ at risk during whole breast radiotherapy using 4DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Feng Xiang Li; Min Xu; Tao Sun; Jie Lu
Journal:  Radiat Oncol       Date:  2013-05-02       Impact factor: 3.481

5.  Dosimetric effects of swelling or shrinking tissue during helical tomotherapy breast irradiation. A phantom study.

Authors:  Rudolf Klepper; Sebastian Höfel; Ulrike Botha; Peter Köhler; Felix Zwicker
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

6.  Cardiac-sparing radiation therapy using positioning breast shell for patients with left-sided breast cancer who are ineligible for breath-hold techniques.

Authors:  Kurian Joseph; Heather Warkentin; Sunita Ghosh; Lee-Anne Polkosnik; Kent Powell; Matthew Brennan; Brad Warkentin; Johanna Jacobs; Khalifa Alkaabi; Susan Chafe; Keith Tankel; Zsolt Gabos; Hong-Wei Liu; Patricia Tai
Journal:  Adv Radiat Oncol       Date:  2017-08-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.