One-year outcomes of Neoss bimodal implants. A prospective clinical, radiographic, and RFA study.

Lars Sennerby1, Peter Andersson, Damiano Verrocchi, Rauno Viinamäki.   

Abstract

BACKGROUND: The Neoss implant system has been available since 2004. Few studies documenting the clinical performance of this implant are available.
PURPOSE: To study the stability and clinical/radiographic outcomes of Neoss implants 1 year of loading when using a two-stage protocol.
MATERIALS AND METHODS: Ninety (90) consecutive patients scheduled for implant treatment using a two-stage procedure were enrolled in a prospective follow-up study. A total of 218 implants (Neoss System, Bimodal surface, Neoss Ltd, Harrogate, UK) in diameters of 3.5, 4.0, and 4.5 mm and in lengths from 7 to 15 mm were placed to support 29 single tooth replacements, 53 partial bridges, 5 full bridges, and 10 overdentures in both jaws. Abutment connection was made after a healing period of 3-4 months. The patients were followed during 1 year of loading with clinical, radiographic, and resonance frequency analysis (Osstell Mentor™, Osstell AB, Gothenburg, Sweden) examinations. Prostheses were removed at the annual check-up for individual testing of implant stability.
RESULTS: Three implant failures were experienced, giving a survival rate of 98.6% after 1 year. A mean bone loss of 0.6 mm (SD 0.8) was observed after 1 year. There was a significant inverse correlation between implant diameter and marginal bone loss (p < .003). The mean implant stability quotient levels were 73.7 (SD 7.6), 74.4 (SD 6.4), and 76.7 (SD 5.2) at placement, abutment connection, and first annual check-up, respectively. The stability had increased significantly from placement to 1 year (p < .001) and from abutment to 1 year (p < .0001). Implant stability was higher in the mandible than in the maxilla at all time points. There was a significant correlation between bone quality and stability at placement (p < .0001) and abutment connection (p < .001) but not after 1 year.
CONCLUSIONS: The use of Neoss implants for prosthetic rehabilitation of consecutive edentate patients with different needs resulted in predictable clinical and radiographic outcomes after 1 year of loading. Implant stability measurements revealed a favorable bone tissue reaction to the implants.
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20345985     DOI: 10.1111/j.1708-8208.2010.00273.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

Authors:  Mirko Mikic; Zoran Vlahovic; Momir Stevanović; Zoran Arsic; Rasa Mladenovic
Journal:  Tomography       Date:  2022-05-11

2.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

3.  Clinical and radiographic evaluation of new dental implant system: Results of a 3-year prospective study.

Authors:  Seçil Karakoca Nemli; Merve Bankoğlu Güngör; Cemal Aydın; Handan Yılmaz; Bilge Turhan Bal; Yeliz Kaşko Arıcı
Journal:  J Dent Sci       Date:  2015-05-15       Impact factor: 2.080