Abstract

OBJECTIVE: To evaluate changes in femorotibial contact areas (CA) and pressures and meniscal strain after serial meniscectomies of the caudal pole of the medial meniscus. STUDY
DESIGN: Ex vivo biomechanical study. SAMPLE POPULATION: Unpaired pelvic limbs from 8 adult dogs weighing 28-35 kg.
METHODS: All specimens underwent sequentially, a 30% radial width partial meniscectomy, a 75% radial width partial meniscectomy, and a segmental caudal pole hemi-meniscectomy. Digital pressure sensors were used to measure lateral and medial peak and mean contact pressures and areas before and after serial meniscectomies. Meniscal strain was measured under load in the intact meniscus and after 30% and 75% radial width meniscectomy. Repeated measures analysis of variance with a post hoc Bonferroni's test (P<.05) was used for statistical analysis.
RESULTS: A 30% radial width meniscectomy had no significant effect on contact mechanics. A 75% radial width caused a 60.9% increase and hemi-meniscectomy an 87.4% increase in peak contact pressures compared with control. Medial CA decreased by 34.7% after 75% radial width meniscectomy and 47.2% after hemi-meniscectomy. A 30% radial width meniscectomy resulted in 38.5%, and a 75% radial width meniscectomy a 69.2%, decrease in medial meniscal strain compared with control, but these differences were not statistically significant.
CONCLUSIONS: In this cadaveric model, smaller (30%) partial meniscectomies had minimal effect on the biomechanics of meniscal function, whereas larger partial (75%) and segmental meniscectomies resulted in significant changes in meniscal and femorotibial contact mechanics. CLINICAL RELEVANCE: This ex vivo data should be considered in clinical decision making for treatment of meniscal problems in dogs.

Entities:  

Mesh:

Year:  2010        PMID: 20345523     DOI: 10.1111/j.1532-950X.2010.00668.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  5 in total

1.  Influence of partial meniscectomy on attachment forces, superficial strain and contact mechanics in porcine knee joints.

Authors:  Maren Freutel; Andreas M Seitz; Anita Ignatius; Lutz Dürselen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-27       Impact factor: 4.342

2.  Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

Authors:  Andre Leumann; Rafael Fortuna; Tim Leonard; Victor Valderrabano; Walter Herzog
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-02       Impact factor: 4.342

3.  Changes in in vitro compressive contact stress in the rat tibiofemoral joint with varus loading.

Authors:  Mack Gardner-Morse; Gary Badger; Bruce Beynnon; Maria Roemhildt
Journal:  J Biomech       Date:  2013-02-12       Impact factor: 2.712

4.  Intra-articular Implantation of Mesenchymal Stem Cells, Part 1: A Review of the Literature for Prevention of Postmeniscectomy Osteoarthritis.

Authors:  Matthew J Kraeutler; Justin J Mitchell; Jorge Chahla; Eric C McCarty; Cecilia Pascual-Garrido
Journal:  Orthop J Sports Med       Date:  2017-01-19

5.  Effect of lateral meniscectomy and osteochondral grafting of a lateral femoral condylar defect on contact mechanics: a cadaveric study in dogs.

Authors:  Christina J Choate; Stanley E Kim; Caleb C Hudson; David Spreng; Antonio Pozzi
Journal:  BMC Vet Res       Date:  2013-03-22       Impact factor: 2.741

  5 in total