Literature DB >> 20337620

Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins.

J McElwain1, M A Malik, B H Harte, N M Flynn, J G Laffey.   

Abstract

The C-MAC comprises a Macintosh blade connected to a video unit. The familiarity of the Macintosh blade, and the ability to use the C-MAC as a direct or indirect laryngoscope, may be advantageous. We wished to compare the C-MAC with Macintosh, Glidescope and Airtraq laryngoscopes in easy and simulated difficult laryngoscopy. Thirty-one experienced anaesthetists performed tracheal intubation in an easy and difficult laryngoscopy scenario. The duration of intubation attempts, success rates, number of intubation attempts and of optimisation manoeuvres, the severity of dental compression, and difficulty of device use were recorded. In easy laryngoscopy, the duration of tracheal intubation attempts were similar with the C-MAC, Macintosh and Airtraq laryngoscopes; the Glidescope performed less well. The C-MAC and Airtraq provided the best glottic views, but the C-MAC was rated as the easiest device to use. In difficult laryngo-scopy the C-MAC demonstrated the shortest tracheal intubation times. The Airtraq provided the best glottic view, with the Macintosh providing the worst view. The C-MAC was the easiest device to use.

Mesh:

Year:  2010        PMID: 20337620     DOI: 10.1111/j.1365-2044.2010.06307.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  27 in total

1.  A comparison of video laryngoscopy to direct laryngoscopy for the emergency intubation of trauma patients.

Authors:  Maria Michailidou; Terence O'Keeffe; Jarrod M Mosier; Randall S Friese; Bellal Joseph; Peter Rhee; John C Sakles
Journal:  World J Surg       Date:  2015-03       Impact factor: 3.352

2.  Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization.

Authors:  Nidhi Gupta; Girija Prasad Rath; Hemanshu Prabhakar
Journal:  J Anesth       Date:  2013-03-11       Impact factor: 2.078

3.  A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study.

Authors:  Kuo-Chuan Hung; Ping-Heng Tan; Victor Chia-Hsiang Lin; Hao-Kuang Wang; Hung-Shu Chen
Journal:  J Anesth       Date:  2012-10-07       Impact factor: 2.078

4.  Comparison of Macintosh, McCoy and C-MAC D-Blade video laryngoscope intubation by prehospital emergency health workers: a simulation study.

Authors:  Ahmet Yildirim; Hasan A Kiraz; İbrahim Ağaoğlu; Okhan Akdur
Journal:  Intern Emerg Med       Date:  2016-03-21       Impact factor: 3.397

Review 5.  Clinical consensus of emergency airway management.

Authors:  Feng Sun; Ya Wang; Shicheng Ma; Huadong Zhu; Xuezhong Yu; Jun Xu
Journal:  J Thorac Dis       Date:  2017-11       Impact factor: 2.895

6.  [Direct laryngoscopy or C-MAC video laryngoscopy? Routine tracheal intubation in patients undergoing ENT surgery].

Authors:  D Meininger; U Strouhal; C F Weber; D Fogl; L Holzer; K Zacharowski; C Byhahn
Journal:  Anaesthesist       Date:  2010-08-13       Impact factor: 1.041

7.  A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department.

Authors:  Jarrod Mosier; Stephen Chiu; Asad E Patanwala; John C Sakles
Journal:  Ann Emerg Med       Date:  2013-01-30       Impact factor: 5.721

8.  Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways.

Authors:  Alper Kılıçaslan; Ahmet Topal; Atilla Erol; Sema Tuncer Uzun
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-08-01

9.  A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia.

Authors:  Erol Cavus; Carsten Thee; Thora Moeller; Joerg Kieckhaefer; Volker Doerges; Klaus Wagner
Journal:  BMC Anesthesiol       Date:  2011-03-01       Impact factor: 2.217

10.  Comparative evaluation of intubation performances using two different barrier devices used in the COVID-19 era: A manikin based pilot study.

Authors:  Ashish Kannaujia; Rudrashish Haldar; Rafat Shamim; Prabhakar Mishra; Anil Agarwal
Journal:  Saudi J Anaesth       Date:  2021-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.