Literature DB >> 20337384

Electrocatalytic microelectrode detectors for choline and acetylcholine following separation by capillary electrophoresis.

Jhindan Mukherjee1, Jon R Kirchhoff.   

Abstract

Two electrocatalytic enzyme modified microelectrode systems were employed as end-column amperometric detectors of choline (Ch) and acetylcholine (ACh) following separation by capillary electrophoresis (CE). Horseradish peroxidase cross-linked in an osmium based redox polymer hydrogel (HRP-Os) was physically adsorbed on Au microelectrodes followed by chemical cross-linking of the enzymes acetylcholinesterase (AChE) and choline oxidase (ChO). An alternative approach utilized the deposition of the transition metal catalyst, Prussian Blue (PB), on Pt microelectrodes as the electrocatalyst. Utilizing butyrylcholine (BuCh) as an internal standard, the HRP-Os/AChE-ChO and PB/AChE-ChO electrodes exhibited excellent linear responses from 2-2000 microM and 10-2000 microM, respectively, for both Ch and ACh. Detection limits of 0.1 microM or 38 amol were determined for the HRP-Os/AChE-ChO electrode. The limit of detection for ACh and Ch at the PB/AChE-ChO electrode was 5 microM or 9.5 fmol. The electrodes were operated at potentials of +0.10 and -0.10 V vs Ag/AgCl (3 M NaCl), respectively, and thus minimized the potential response from oxidizable interferences. In addition, both electrocatalytic electrodes showed good operational stability for more than 70 h. The enhanced detection capability of the HRP-Os/AChE-ChO and PB/AChE-ChO electrodes in combination with efficient CE separation of Ch and ACh provides a new sensitive and selective strategy for monitoring and quantifying these cholinergic biomarkers in biological fluids.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20337384      PMCID: PMC2867047          DOI: 10.1021/ac9010843

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  26 in total

Review 1.  Separation methods used in the determination of choline and acetylcholine.

Authors:  T H Tsai
Journal:  J Chromatogr B Biomed Sci Appl       Date:  2000-09-29

Review 2.  Recent advances in the application of capillary electrophoresis to neuroscience.

Authors:  Paula R Powell; Andrew G Ewing
Journal:  Anal Bioanal Chem       Date:  2005-02-23       Impact factor: 4.142

3.  Analysis of acetylcholine and choline in microdialysis samples by liquid chromatography/tandem mass spectrometry.

Authors:  Päivi Uutela; Ruut Reinilä; Petteri Piepponen; Raimo A Ketola; Risto Kostiainen
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

4.  Classification of the mode of inhibition of high-affinity choline uptake using capillary electrophoresis with electrochemical detection at an enzyme-modified microelectrode.

Authors:  Tatyana V Barkhimer; Jon R Kirchhoff; Richard A Hudson; William S Messer
Journal:  Anal Biochem       Date:  2005-04-15       Impact factor: 3.365

5.  Microdialysis coupled on-line to capillary liquid chromatography with tandem mass spectrometry for monitoring acetylcholine in vivo.

Authors:  Holly M Shackman; Minshan Shou; Nicholas A Cellar; Christopher J Watson; Robert T Kennedy
Journal:  J Neurosci Methods       Date:  2006-07-28       Impact factor: 2.390

6.  Improved analysis of acetylcholine and choline in canine brain and blood samples by capillary gas chromatography-mass spectrometry.

Authors:  A K Singh; L R Drewes
Journal:  J Chromatogr       Date:  1985-04-12

7.  Evaluation of the inhibition of choline uptake in synaptosomes by capillary electrophoresis with electrochemical detection.

Authors:  Tatyana V Barkhimer; Jon R Kirchhoff; Richard A Hudson; William S Messer
Journal:  Electrophoresis       Date:  2002-11       Impact factor: 3.535

8.  Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer.

Authors:  M G Garguilo; N Huynh; A Proctor; A C Michael
Journal:  Anal Chem       Date:  1993-03-01       Impact factor: 6.986

9.  Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode.

Authors:  Haibin Shi; Yu Yang; Jiadong Huang; Zixia Zhao; Xinhua Xu; Jun-Ichi Anzai; Tetsuo Osa; Qiang Chen
Journal:  Talanta       Date:  2006-03-23       Impact factor: 6.057

10.  High-performance liquid chromatography/tandem mass spectrometry assay for the rapid high sensitivity measurement of basal acetylcholine from microdialysates.

Authors:  Mark E P Hows; Andrew J Organ; Sarah Murray; Lee A Dawson; Richard Foxton; Christian Heidbreder; Zoë A Hughes; Laurent Lacroix; Ajit J Shah
Journal:  J Neurosci Methods       Date:  2002-11-15       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.