Literature DB >> 20335755

The effect of entry point on malalignment and iatrogenic fracture with the Synthes lateral entry femoral nail.

Mark L Prasarn1, Monica Daegl Cattaneo, Timothy Achor, Jaimo Ahn, Craig E Klinger, David L Helfet, Dean G Lorich.   

Abstract

PURPOSE: Multiplanar rigid femoral nails introduced through a lateral entry portal have been associated with a higher risk of iatrogenic fracture and malreduction. This study was designed to investigate if the entry point of the lateral entry femoral nail (Synthes, Paoli, PA) has an impact on alignment of the femur and the incidence of iatrogenic fracture.
MATERIALS AND METHODS: The preoperative and postoperative radiographs of 227 femoral shaft fractures stabilized with the lateral entry femoral nail from 11 different trauma centers were retrospectively evaluated. Reviewers were blinded with respect to outcome and determined whether the starting point for the nail was anterior, middle, or posterior by dividing the greater trochanter into thirds. The corresponding alignment in both the sagittal and coronal planes was determined independently. The occurrence of iatrogenic fractures was documented as well.
RESULTS: Of the 227 radiographs reviewed, 167 had acceptable lateral radiographs of the proximal femur to determine the exact location of the entry point. There was high interobserver reliability (kappa = 0.87) with regard to the scoring of starting point for the nail. The results for the concordant pairs (n = 154) were as follows: middle third 47%, anterior third 44%, and posterior third 10%. The risk of valgus malalignment is nearly threefold (10% versus 25%) when the starting point is anterior as compared with the middle entry point (risk ratio, 2.6; 95% confidence interval, 1.2-5.9; P = 0.021). There was no association between entry site and varus or apex-anteroposterior angulation. There were a total of 16 iatrogenic fractures in the cohort. Ten of these had adequate lateral hip radiographs, and of these, nine occurred after an anterior entry site. There is strong evidence that an anterior insertion site leads to iatrogenic fracture as compared with a middle entry portal (13% versus 0%, P = 0.001).
CONCLUSIONS: Accurate entry site within the greater trochanter is essential to prevent malalignment and iatrogenic fractures when using the lateral entry femoral nail to stabilize fractures of the femoral diaphysis. The helical shape of the nail can result in valgus malalignment and fracture if the entry point is too anterior, and surgeons must recognize these consequences of insertion inaccuracy. Meticulous biplanar imaging and experience with this particular implant are important for its precise and safe insertion.

Entities:  

Mesh:

Year:  2010        PMID: 20335755     DOI: 10.1097/BOT.0b013e3181bedcc1

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  5 in total

1.  [Experiences with a helical femoral nail (LFN®). A multicenter study].

Authors:  J R Rether; J M Muñoz Vives; H J Bail; M H Verhofstad; M Blauth; J Ljungqvist; D Höntzsch
Journal:  Unfallchirurg       Date:  2013-07       Impact factor: 1.000

2.  The characteristics and influence of iatrogenic fracture comminution following antegrade interlocking nailing for simple femoral shaft fractures, a retrospective cohort study.

Authors:  Jou-Hua Wang; Hao-Chun Chuang; Wei-Ren Su; Wei-Lun Chang; Fa-Chuan Kuan; Chih-Kai Hong; Kai-Lan Hsu
Journal:  BMC Musculoskelet Disord       Date:  2022-05-14       Impact factor: 2.562

Review 3.  Rigid intramedullary nail fixation of femoral fractures in adolescents: what evidence is available?

Authors:  D S Angadi; D E T Shepherd; R Vadivelu; T Barrett
Journal:  J Orthop Traumatol       Date:  2013-09-29

4.  Retrograde entry portal for femoral interlocking nailing in femoral nonunion after plate failure: a prospective comparative study with antergrade portal.

Authors:  Yasser Assaghir
Journal:  J Orthop Traumatol       Date:  2016-07-20

5.  Time to entry point and distal locking of intramedullary nails: a methodological phantom study comparing biplanar and uniplanar surgical imaging.

Authors:  Peter Ström; Nils P Hailer; Olof Wolf
Journal:  BMC Musculoskelet Disord       Date:  2022-02-24       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.