Literature DB >> 20335088

Partial least squares: a method to estimate efficient channels for the ideal observers.

Joel M Witten1, Subok Park, Kyle J Myers.   

Abstract

We advocate a task-based approach to the assessment of image quality using the Bayesian ideal observer. The Bayesian ideal observer provides an absolute upper bound for performance estimates. However, using the full images as inputs to the observer is often infeasible due to their high dimensionality. A practical alternative is to reduce the dimensionality of the images by applying channels, while approximating the ideal observer by an observer constrained to the channels. Laguerre-Gauss (LG) channels and those derived from the singular value decomposition (SVD) of the system operator have previously been used with the Bayesian ideal observer. However, the channelized observer with LG and SVD channels was only applicable in situations with a rotationally symmetric signal or known system operator, respectively. We investigate a method using partial least squares (PLS) to compute efficient channels directly from the images, without prior knowledge of the background, signal, or system operator. Results show that the channelized ideal observer with PLS channels approximates the nonchannelized observer, and does so with fewer channels than the observer with either LG or SVD channels. The images are reduced from 4096 pixel values to 20 channel outputs, yet preserve the salient information. Furthermore, PLS reveals that the background image statistics provide important information necessary in signal-detection tasks. Overall, PLS is shown to be a viable channel generation method and may be applicable to real-life situations.

Entities:  

Mesh:

Year:  2010        PMID: 20335088     DOI: 10.1109/TMI.2010.2041514

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms.

Authors:  Subok Park; Robert Jennings; Haimo Liu; Aldo Badano; Kyle Myers
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

2.  Lack of agreement between radiologists: implications for image-based model observers.

Authors:  Juhun Lee; Robert M Nishikawa; Ingrid Reiser; Margarita L Zuley; John M Boone
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-03

3.  Comparison of human and Hotelling observer performance for a fan-beam CT signal detection task.

Authors:  Adrian A Sanchez; Emil Y Sidky; Ingrid Reiser; Xiaochuan Pan
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data.

Authors:  Stefano Young; Predrag R Bakic; Kyle J Myers; Robert J Jennings; Subok Park
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

6.  Region of interest based Hotelling observer for computed tomography with comparison to alternative methods.

Authors:  Adrian A Sanchez; Emil Y Sidky; Xiaochuan Pan
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-08

7.  Detection of targets in filtered noise: whitening in space and spatial frequency.

Authors:  Anqi Zhang; Wilson S Geisler
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2022-04-01       Impact factor: 2.104

8.  Method for optimizing channelized quadratic observers for binary classification of large-dimensional image datasets.

Authors:  M K Kupinski; E Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2015-04-01       Impact factor: 2.129

Review 9.  Model observers in medical imaging research.

Authors:  Xin He; Subok Park
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

10.  Human observer performance on in-plane digital breast tomosynthesis images: Effects of reconstruction filters and data acquisition angles on signal detection.

Authors:  Changwoo Lee; Minah Han; Jongduk Baek
Journal:  PLoS One       Date:  2020-03-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.