Literature DB >> 20334996

Computer-assisted navigation software advancements improve the accuracy of total knee arthroplasty.

Ryan G Molli1, Kevin C Anderson, Knute C Buehler, David C Markel.   

Abstract

The purpose of this study was to evaluate the effectiveness of software advancements in improving total knee component positioning and limb alignment when using computer-aided navigation. A single total joint fellowship-trained surgeon performed unilateral total knee arthroplasty on 315 patients using conventional techniques or with assistance from computer navigation software. Preoperative and postoperative x-ray measurements were taken and analyzed. Our previous work demonstrated a statistically significant improvement (P < .02) in limb alignment (±3° of biomechanical neutral) when using version 2.0 software (93%) when compared with conventional techniques (82%). Further improvement was demonstrated with the version 3.1 software (99%, P < .03). The tourniquet times were recorded for each group and showed a significant improvement with the 3.1 software (conventional = 74 minutes, 2.0 navigation = 90 minutes, and 3.1 navigation = 73 minutes). The Stryker 2.0 software (Stryker Orthopedics, Mahwah, NJ) tourniquet time was statistically significantly longer than either the conventional or the 3.1 group (P < .001). Outcomes-based studies will be required to see if these factors will lead to improved patient function and/or prolonged prosthetic survival rates.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20334996     DOI: 10.1016/j.arth.2010.01.002

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  13 in total

1.  Minimally invasive and computer-assisted total knee arthroplasty versus conventional technique: a prospective, randomized study.

Authors:  Zhenxiang Zhang; Beibei Gu; Wei Zhu; Lixian Zhu; Qingsong Li; Yaqing Du
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-09-20

2.  Alignment for total knee replacement: a comparison of kinematic axis versus mechanical axis techniques. A cadaver study.

Authors:  Michael Nogler; William Hozack; Dermot Collopy; Eckart Mayr; Gregory Deirmengian; Kathrin Sekyra
Journal:  Int Orthop       Date:  2012-08-14       Impact factor: 3.075

3.  Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases.

Authors:  Romain Gaillard; Simone Cerciello; Sebastien Lustig; Elvire Servien; Philippe Neyret
Journal:  Int Orthop       Date:  2016-10-13       Impact factor: 3.075

4.  Total knee arthroplasty with a computer-navigated saw: a pilot study.

Authors:  Kevin L Garvin; Andres Barrera; Craig R Mahoney; Curtis W Hartman; Hani Haider
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

5.  Assessing the value of a total joint replacement.

Authors:  David B Bumpass; Ryan M Nunley
Journal:  Curr Rev Musculoskelet Med       Date:  2012-12

6.  Lessons for surgeons in the final moments of Air France Flight 447.

Authors:  Aneel Bhangu; Sonia Bhangu; James Stevenson; Douglas M Bowley
Journal:  World J Surg       Date:  2013-06       Impact factor: 3.352

7.  Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications.

Authors:  Jeffrey J Cherian; Bhaveen H Kapadia; Samik Banerjee; Julio J Jauregui; Kimona Issa; Michael A Mont
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

8.  Which factors increase risk of malalignment of the hip-knee-ankle axis in TKA?

Authors:  Arun B Mullaji; Gautam M Shetty; A P Lingaraju; Sagar Bhayde
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Correction of varus deformity during TKA with reduction osteotomy.

Authors:  Arun B Mullaji; Gautam M Shetty
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

10.  Influence of navigation system updates on total knee arthroplasty.

Authors:  Hiroshi Inui; Shuji Taketomi; Kensuke Nakamura; Seira Takei; Hideki Takeda; Sakae Tanaka; Takumi Nakagawa
Journal:  BMC Sports Sci Med Rehabil       Date:  2013-05-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.