Literature DB >> 20333764

Vertical sandwich-type continuous/evaporative TLC with fixed mobile phase volume for separating sugars of clinical relevance in paper-borne urine and blood samples in newborn screening.

J R Alonso-Fernandez1, M I Carpinteiro, J Baleato, J Fidalgo.   

Abstract

We describe the history and current implementation of an inexpensive thin layer chromatography (TLC) method, vertical sandwich-type continuous/evaporative TLC with fixed mobile phase volume, that is convenient for detecting and identifying reducing sugars of clinical relevance in the paper-borne blood and urine samples collected in neonatal screening programmes. This method facilitates screening by providing a considerable degree of standardization of chromatographic results. Among some 555,000 newborns to which it has been applied, it has detected 10 cases of classical galactosaemia, 7 cases of galactokinase deficiency, 2 cases of glucosuria, and 3 cases of transitory neonatal diabetes mellitus; the only false negatives we are aware of were two cases of galacto-4-epimerase deficiency detected by tandem mass spectrometry. Screening for sugars in urine has allowed the detection of galactosaemia when the accompanying blood sample was invalid because of transfusion or parenteral feeding. The conclusion is that this inexpensive procedure is very useful for the detection of relevant metabolopathies in circumstances where others fail. (c) 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20333764      PMCID: PMC6647655          DOI: 10.1002/jcla.20371

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  8 in total

1.  Procedures for testing urine specimens dried on filter paper.

Authors:  H K BERRY
Journal:  Clin Chem       Date:  1959-12       Impact factor: 8.327

2.  Simple method for detection of phenylketonuria.

Authors:  H K BERRY; B SUTHERLAND; G M GUEST; J WARKANY
Journal:  J Am Med Assoc       Date:  1958-08-30

3.  Newborn screening fact sheets.

Authors:  Celia I Kaye; Frank Accurso; Stephen La Franchi; Peter A Lane; Northrup Hope; Pang Sonya; Schaefer G Bradley; Lloyd-Puryear Michele A
Journal:  Pediatrics       Date:  2006-09       Impact factor: 7.124

4.  Advantages of silica gel as a medium for rapid thin-layer chromatography of neutral sugars.

Authors:  I S Menzies; J N Mount
Journal:  Med Lab Technol       Date:  1975-10

5.  Neonatal screening for galactosemia by quantitative analysis of hexose monophosphates using tandem mass spectrometry: a retrospective study.

Authors:  U G Jensen; N J Brandt; E Christensen; F Skovby; B Nørgaard-Pedersen; H Simonsen
Journal:  Clin Chem       Date:  2001-08       Impact factor: 8.327

6.  Continuous thin-layer chromatography of sugars of clinical interest in samples of urine impregnated on paper.

Authors:  J R Alonso-Fernández; M D Bóveda; C Parrado; J Peña; J M Fraga
Journal:  J Chromatogr       Date:  1981-11-06

7.  Simple and rapid system for screening and identification of reducing sugars in urine.

Authors:  C Auray-Blais; R Giguere; P Draper; D Shapcott; B Lemieux
Journal:  Clin Biochem       Date:  1978-12       Impact factor: 3.281

Review 8.  High-resolution thin-layer chromatography of gangliosides.

Authors:  J Müthing
Journal:  J Chromatogr A       Date:  1996-01-12       Impact factor: 4.759

  8 in total
  1 in total

Review 1.  Novel techniques and newer markers for the evaluation of "proximal tubular dysfunction".

Authors:  Michael Ludwig; Sidharth K Sethi
Journal:  Int Urol Nephrol       Date:  2011-03-01       Impact factor: 2.370

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.