Literature DB >> 20332731

Knee isokinetic test-retest: a multicentre knee isokinetic test-retest study of a fatigue protocol.

A Saenz1, M Avellanet, E Hijos, J Chaler, R Garreta, E Pujol, B Sandoval, C Buen, A Farreny.   

Abstract

AIM: The aim of this study was to establish the test-retest reliability of a knee extensor and flexor muscle fatigue protocol using a biodex system 3 isokinetic dynamometer.
METHODS: Three-outpatient Rehabilitation Departments undertook the study. Fatigue was evaluated in the dominant knee of 90 healthy female volunteers, non-sportswomen, aged between 20 and 40. They performed 40 consecutive concentric knee flexions and extensions, at 120 degrees /s, on a Biodex 3 isokinetic dynamometer. Two evaluations were done over a period of seven days. Analysed variables were: maximal repetition of total work, maximal work repetition number, work to body weight ratio, total work, work during first and last third of the protocol, fatigue ratio, work fatigue. Statistical analysis determined mean values, medians and box-plots. Intraclass Correlation Coefficients (ICC) (confidence interval 95 %), t-test and one-way analysis of variance (ANOVA) evaluated reliability. Difference of means (di), standard error of measurement (SEM) and 95% of interval confidence (IC di) were also calculated (P<0.05).
RESULTS: All participants completed the study. Reliability data were excellent (ICC>0.75) for total work (0.85), work during first third (0.80) and last third (0.80) in extension, and for total work in flexion. Reliability data were fair to good (ICC 0.4-0.75) for the rest of the variables. Median varied less than 20% in all cases during test-retest.
CONCLUSION: This knee fatigue protocol is reliable for flexion and extension, above all when using the total work as a variable. The desirability of multicentre studies in rehabilitation and standardisation of protocols is emphasised.

Entities:  

Mesh:

Year:  2010        PMID: 20332731

Source DB:  PubMed          Journal:  Eur J Phys Rehabil Med        ISSN: 1973-9087            Impact factor:   2.874


  11 in total

1.  Increased leg muscle fatigability during 2 mA and 4 mA transcranial direct current stimulation over the left motor cortex.

Authors:  Craig D Workman; John Kamholz; Thorsten Rudroff
Journal:  Exp Brain Res       Date:  2020-01-09       Impact factor: 1.972

2.  Shoulder muscle endurance: the development of a standardized and reliable protocol.

Authors:  Jean-Sébastien Roy; Bryan Ma; Joy C Macdermid; Linda J Woodhouse
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2011-01-11

3.  Evaluation and imaging of an untreated grade III hamstring tear: a case report.

Authors:  Brett B Clark; David Jaffe; R Frank Henn; Richard M Lovering
Journal:  Clin Orthop Relat Res       Date:  2011-08-18       Impact factor: 4.176

4.  Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia.

Authors:  U Gunnarsson; M Johansson; K Strigård
Journal:  Hernia       Date:  2011-03-05       Impact factor: 4.739

5.  STRENGTH AND FATIGUE MEASUREMENTS OF THE HIP FLEXOR AND HIP EXTENSOR MUSCLES: TEST-RETEST RELIABILITY AND LIMB DOMINANCE EFFECT.

Authors:  Monica Millisdotter Krantz; Martin Åström; Anna Maria Drake
Journal:  Int J Sports Phys Ther       Date:  2020-12

6.  Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.

Authors:  Dragana Dragicevic Cvjetkovic; Sinisa Bijeljac; Stanislav Palija; Goran Talic; Tatjana Nozica Radulovic; Milkica Glogovac Kosanovic; Slavko Manojlovic
Journal:  Med Arch       Date:  2015-02-21

7.  Effects of Motor Learning on Clinical Isokinetic Test Performance in Knee Osteoarthritis Patients.

Authors:  José Messias Rodrigues-da-Silva; Márcia Uchoa de Rezende; Tânia Carvalho Spada; Lucila da Silva Francisco; Júlia Maria D'Andréa Greve; Emmanuel Gomes Ciolac
Journal:  Clinics (Sao Paulo)       Date:  2017-04       Impact factor: 2.365

8.  Different Effects of 2 mA and 4 mA Transcranial Direct Current Stimulation on Muscle Activity and Torque in a Maximal Isokinetic Fatigue Task.

Authors:  Craig David Workman; Alexandra C Fietsam; Thorsten Rudroff
Journal:  Front Hum Neurosci       Date:  2020-06-25       Impact factor: 3.169

9.  Transcranial Direct Current Stimulation at 4 mA Induces Greater Leg Muscle Fatigability in Women Compared to Men.

Authors:  Craig D Workman; Alexandra C Fietsam; Thorsten Rudroff
Journal:  Brain Sci       Date:  2020-04-21

10.  Test-retest reliability of innovated strength tests for hip muscles.

Authors:  Christophe Meyer; Kristoff Corten; Mariska Wesseling; Koen Peers; Jean-Pierre Simon; Ilse Jonkers; Kaat Desloovere
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.