Literature DB >> 20331376

Reproducibility of a measurement for latissimus dorsi muscle length.

John D Borstad1, Matthew S Briggs.   

Abstract

ABSTRACT Latissimus dorsi is a muscle theorized to undergo length changes due to shoulder region pathology or treatment such as stretching. A latissimus dorsi length measurement would be valuable to determine if length changes have occurred within an individual over time. With no such measurement known, we examined a proposed technique believed to isolate latissimus dorsi. The aim of this study was to determine how accurately a rater could reproduce this measurement in the same individual over a 6-week interval. Thirty subjects without shoulder symptoms were measured at 6-week intervals by either an experienced or novice clinician. A repeated-measures analysis of variance estimated the measurement error used for calculating intrarater correlation coefficients (ICC(3,1)). The standard error of measurement (SEM), confidence intervals (CI), and the smallest real difference (SRD) were also determined. The ICCs for all raters combined and for the separate groups indicated poor reliability. The SEM and SRD values were similar between groups, but they suggest poor measurement reproducibility in the same subject over a 6-week interval. This technique is not recommended for measuring latissimus dorsi length clinically to assess within-subject change over time.

Entities:  

Mesh:

Year:  2010        PMID: 20331376     DOI: 10.3109/09593980903015250

Source DB:  PubMed          Journal:  Physiother Theory Pract        ISSN: 0959-3985            Impact factor:   2.279


  3 in total

1.  Regarding the Necessity of Functional Assessment Including Motor Control Assessment of Post-Mastectomy Patients Qualified for Latissimus Dorsi Breast Reconstruction Procedure-Pilot Study.

Authors:  Rita Hansdorfer-Korzon; Damian Wnuk; Jakub Ławnicki; Maciej Śliwiński; Agnieszka Gruszecka
Journal:  Int J Environ Res Public Health       Date:  2020-04-21       Impact factor: 3.390

2.  The agreement and repeatability of measurements of ankle joint dorsiflexion and poplietal angle in healthy adolescents.

Authors:  Krzysztof Pietrzak; Izabela Miechowicz; Krzysztof Nowocień; Bartosz Kraszewski; Piotr Rzymski
Journal:  J Foot Ankle Res       Date:  2022-09-07       Impact factor: 3.050

3.  Inter- and intra-rater reliability of a technique assessing the length of the Latissimus Dorsi muscle.

Authors:  Muhammad Dawood; Piet J Bekker; Agatha J van Rooijen; Elzette Korkie
Journal:  S Afr J Physiother       Date:  2018-03-13
  3 in total