Literature DB >> 20329721

Cleavage-sensing redox peptide monolayers for the rapid measurement of the proteolytic activity of trypsin and alpha-thrombin enzymes.

Jocelyne Adjémian1, Agnès Anne, Gilles Cauet, Christophe Demaille.   

Abstract

Ferrocene (Fc)-labeled peptides are end-grafted onto gold electrodes via a flexible polyethylene glycol (PEG) linker, and their ability to act as substrates for proteolytic enzymes trypsin and alpha-thrombin is investigated by cyclic voltammetry. It is shown that whereas a short Fc-tetrapeptide substrate is rapidly cleaved by trypsin, a longer Fc-heptapeptide substrate is required for alpha-thrombin detection. However, in both cases it is observed that not all of the Fc-peptide chains present on the electrode surface are cleavable by the proteases and that the cleavage yield is actually controlled by the surface coverage in the Fc-peptide. Surface dilution of the Fc-peptide using a backfilling molecule such as MCH (6-mercapto-1-hexanol) was required to obtain a cleavage yield larger than 80%. The kinetics of Fc-peptide cleavage by trypsin or alpha-thrombin is then shown to be adequately described by Michaelis Menten kinetics, allowing enzymatic constants k(cat) and K(M) to be determined. The obtained rate constant values showed that the affinity of the enzymes for their respective Fc-peptide substrates is very high (i.e., low K(M) values) whereas that for the cleavage step itself is relatively low (low k(cat) values). Partial compensation of these parameters yields a fast response of the Fc-peptide electrodes to the proteases in solution in the 1-1000 nM range. The type of molecule used to backfill the Fc-peptide layers, either MCH or PEG(6) chains, is shown to modulate the activity of the proteases versus the Fc-peptide layers: in particular, the PEG(6) diluent is specifically shown to decrease the ability of alpha-thrombin to cleave its Fc-peptide substrate whereas trypsin activity is unaffected by the presence of PEG chains.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20329721     DOI: 10.1021/la100397g

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  6 in total

1.  Quantitative electrochemical detection of cathepsin B activity in complex tissue lysates using enhanced AC voltammetry at carbon nanofiber nanoelectrode arrays.

Authors:  Luxi Z Swisher; Allan M Prior; Stephanie Shishido; Thu A Nguyen; Duy H Hua; Jun Li
Journal:  Biosens Bioelectron       Date:  2014-01-10       Impact factor: 10.618

2.  Electrochemical Activity Assay for Protease Analysis Using Carbon Nanofiber Nanoelectrode Arrays.

Authors:  Yang Song; Huafang Fan; Morgan J Anderson; Jestin Gage Wright; Duy H Hua; Jessica Koehne; M Meyyappan; Jun Li
Journal:  Anal Chem       Date:  2019-02-15       Impact factor: 6.986

3.  Assembly, structure and thermoelectric properties of 1,1'-dialkynylferrocene 'hinges'.

Authors:  Luke A Wilkinson; Troy L R Bennett; Iain M Grace; Joseph Hamill; Xintai Wang; Sophie Au-Yong; Ali Ismael; Samuel P Jarvis; Songjun Hou; Tim Albrecht; Lesley F Cohen; Colin Lambert; Benjamin J Robinson; Nicholas J Long
Journal:  Chem Sci       Date:  2022-06-27       Impact factor: 9.969

4.  Electrochemical Protease Biosensor Based on Enhanced AC Voltammetry Using Carbon Nanofiber Nanoelectrode Arrays.

Authors:  Luxi Z Swisher; Lateef U Syed; Allan M Prior; Foram R Madiyar; Kyle R Carlson; Thu A Nguyen; Duy H Hua; Jun Li
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2013-02-28       Impact factor: 4.126

5.  Photoactivated Spatiotemporally-Responsive Nanosensors of in Vivo Protease Activity.

Authors:  Jaideep S Dudani; Piyush K Jain; Gabriel A Kwong; Kelly R Stevens; Sangeeta N Bhatia
Journal:  ACS Nano       Date:  2015-11-13       Impact factor: 15.881

6.  A Novel Photoelectrochemical Biosensor for Tyrosinase and Thrombin Detection.

Authors:  Jiexia Chen; Yifan Liu; Guang-Chao Zhao
Journal:  Sensors (Basel)       Date:  2016-01-21       Impact factor: 3.576

  6 in total