Shielding effects of Selectron applicator and pellets on isodose distributions.

R A Siwek1, P F O'Brien, P M Leung.   

Abstract

The Selectron is a mobile remote afterloading device which was developed specifically to reduce the radiation exposure to hospital personnel during intracavitary brachytherapy. Applicators for these devices contain source trains of 48 spherical pellets per channel, composed of both active and inactive pellets which have an external diameter of 2.5 mm. The configuration of pellets is chosen to optimize the dose distribution in accordance with the patient's geometry. A new dose calculation model has been proposed based on the separation of radiation into primary and secondary components. This model takes into account the attenuation of the primary radiation by the pellets. Isodose distributions around a Selectron standard applicator containing a typical patient loading of active pellets were measured and compared with those calculated by program SEEDS of the Atomic Energy of Canada Ltd. (AECL) Theraplan computer planning system. The shielding effects of the stainless steel applicator tubes, the ovoids, screws, inactive and active pellets will be considered. The effects of scatter and attenuation by the pellets will be illustrated by measured isodose distributions around a single applicator tube.

Entities:  

Mesh:

Year:  1991        PMID: 2031088     DOI: 10.1016/0167-8140(91)90147-9

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  Independent evaluation of an in-house brachytherapy treatment planning system using simulation, measurement and calculation methods.

Authors:  M A Mosleh Shirazi; R Faghihi; Z Siavashpour; H A Nedaie; S Mehdizadeh; S Sina
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

2.  Developing a Treatment Planning Software Based on TG-43U1 Formalism for Cs-137 LDR Brachytherapy.

Authors:  Sedigheh Sina; Reza Faghihi; Ali Soleimani Meigooni; Zahra Siavashpour; Mohammad Amin Mosleh-Shirazi
Journal:  Iran Red Crescent Med J       Date:  2013-08-05       Impact factor: 0.611

3.  Impact of the vaginal applicator and dummy pellets on the dosimetry parameters of Cs-137 brachytherapy source.

Authors:  Sedigheh Sina; Reza Faghihi; Ali S Meigooni; Simin Mehdizadeh; M Amin Mosleh Shirazi; Mehdi Zehtabian
Journal:  J Appl Clin Med Phys       Date:  2011-05-19       Impact factor: 2.243