Literature DB >> 20309819

Imaging of active multiple sclerosis plaques: efficiency of contrast-enhanced magnetization transfer subtraction technique.

Oktay Algin1, Bahattin Hakyemez, Ozlem Taşkapilioğlu, Müfit Parlak, Faruk Turan.   

Abstract

PURPOSE: T1-weighted (T1W) magnetic resonance images with magnetization transfer (MT) are widely used in the evaluation of multiple sclerosis (MS) plaques. We aimed to evaluate the contribution of the subtraction technique with MT in the detection of acute MS plaques.
MATERIALS AND METHODS: Sixty-four patients during an MS attack were enrolled in the study. Axial T1W spin echo (SE) with MT, axial-sagittal T2W fast SE, axial FLAIR and postcontrast axial T1W SE magnetic resonance imaging sequence with MT were acquired from all patients. The subtraction (postcontrast-precontrast) images were obtained on the workstation. FLAIR and T2W images were used as reference for plaque imaging. Contrast material enhanced plaques were considered as acute plaques. Qualitatively, both subtracted and contrast-enhanced with MT images were evaluated visually. Quantitatively, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated.
RESULTS: A total of 464 plaques were detected on T2W and FLAIR images. Thirty-five acute plaques were detected on both postcontrast MT and subtracted images. Additionally, 66 acute plaques were only detected on subtracted images visually. CNR and SNR values of acute MS plaques were significantly higher on subtracted MT images than on postcontrast MT images (P < 0.001).
CONCLUSION: The subtraction technique seems to facilitate the detection of acute MS plaques by intensifying the visibility of poorly enhanced plaques without use of high dose contrast medium. We suggest the use of subtraction technique in routine imaging work-up of MS patients with acute attacks.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20309819     DOI: 10.4261/1305-3825.DIR.2879-09.1

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  4 in total

1.  Cerebral lesions of multiple sclerosis: is gadolinium always irreplaceable in assessing lesion activity?

Authors:  Constantina Andrada Treabă; Rodica Bălaşa; Daniela Maria Podeanu; Iunius Paul Simu; Mircea Marian Buruian
Journal:  Diagn Interv Radiol       Date:  2014 Mar-Apr       Impact factor: 2.630

2.  Unusual patient with multiple sclerosis and shunt-responsive normal-pressure hydrocephalus.

Authors:  O Algin; O Taskapilioglu; B Hakyemez; M Parlak
Journal:  Clin Neuroradiol       Date:  2011-04-02       Impact factor: 3.649

3.  Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

Authors:  Richard Keith Downs; Mariah Haider Bashir; Chin Kau Ng; Jens Olaf Heidenreich
Journal:  Quant Imaging Med Surg       Date:  2013-06

4.  T1w dark blood imaging improves detection of contrast enhancing lesions in multiple sclerosis.

Authors:  Christian Thaler; Tanja Schneider; Jan Sedlacik; Daniel Kutzner; Jan-Patrick Stellmann; Christoph Heesen; Jens Fiehler; Susanne Siemonsen
Journal:  PLoS One       Date:  2017-08-10       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.