Literature DB >> 20309442

Selective ionization of melamine in powdered milk by using argon direct analysis in real time (DART) mass spectrometry.

A John Dane1, Robert B Cody.   

Abstract

5-Hydroxymethylfurfural (5-HMF) is a compound with the elemental composition C(6)H(6)O(3) that is present in powdered milk. Protonated 5-HMF (calculated m/z 127.0395) has the same nominal m/z as protonated melamine (calculated m/z 127.0732) and can interfere with direct analysis of melamine in powdered milk. Tandem mass spectrometry and high-resolution mass spectrometry have been previously used to distinguish melamine from 5-HMF. An alternative approach is presented here that uses the direct analysis in real time (DART) ion source operated with argon gas in combination with acetylacetone and pyridine reagent gases to selectively ionize melamine and eliminate the interference from 5-HMF. High-resolution/accurate mass data were used to verify the elimination of the 5-HMF interference and confirm the melamine elemental composition. With further refinement, this technique could lead to a rapid analysis method for screening large numbers of samples.

Entities:  

Year:  2010        PMID: 20309442     DOI: 10.1039/b923561b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

Review 1.  Recent developments in the detection of melamine.

Authors:  Yuan Liu; Ewen E D Todd; Qiang Zhang; Jiang-rong Shi; Xian-jin Liu
Journal:  J Zhejiang Univ Sci B       Date:  2012-07       Impact factor: 3.066

2.  Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS.

Authors:  ShuQi An; Shuai Liu; Jie Cao; ShiFang Lu
Journal:  J Am Soc Mass Spectrom       Date:  2019-07-31       Impact factor: 3.109

3.  Study of Photocatalytic Nano-Particle Effects on the Low Temperature Plasma Ionization Mass Spectrometry.

Authors:  Dan Bee Kim; Sohee Yoon
Journal:  J Am Soc Mass Spectrom       Date:  2018-09-20       Impact factor: 3.109

4.  The Ion Source of Nitrogen Direct Analysis in Real-Time Mass Spectrometry as a Highly Efficient Reactor: Generation of Reactive Oxygen Species.

Authors:  Rui Su; Wenjing Yu; Kaiju Sun; Jie Yang; Changbao Chen; Wenhui Lian; Shuying Liu; Hongmei Yang
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-19       Impact factor: 3.109

5.  Fast Determination of Ingredients in Solid Pharmaceuticals by Microwave-Enhanced In-Source Decay of Microwave Plasma Torch Mass Spectrometry.

Authors:  Rui Su; Xinchen Wang; Changming Hou; Meiling Yang; Keke Huang; Huanwen Chen
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-19       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.