Literature DB >> 20307745

The self-adjusting file (SAF). Part 2: mechanical analysis.

Rafael Hof1, Valery Perevalov, Moshe Eltanani, Raviv Zary, Zvi Metzger.   

Abstract

INTRODUCTION: The study was designed to explore the mechanical properties of the self-adjusting file (SAF) and its application in the root canal using continuous irrigation.
METHODS: The compressibility of the SAF file and the resulting peripheral force were measured using specially designed systems. The abrasivity of the file was tested on dentin blocks representing a flat root canal. The durability of the SAF file was tested using a functional fatigue-to-failure assay. Degradation of the file was evaluated by using files that were previously used for 10, 20, and 30 minutes and comparing their efficacy with that of new, unused files. The potential of extruding irrigant beyond the apex was explored in roots with an open apical foramen.
RESULTS: The SAF file was elastically compressible from a diameter of 1.5 mm to dimensions similar to those of a #20 stainless steel K-file. This compression resulted in an evenly applied force to the root canal walls. The in-and-out vibration of the file and the peripheral force, combined with its abrasivity, allow for hard-tissue removal. Under the conditions of the experiment, no mechanical failure was observed with up to 29 minutes of operation in the root canal. The file loses its efficacy after prolonged use, with a 40% reduction after 30 minutes of operation. The operation of the file with continuous irrigation did not push the irrigant beyond an open apical foramen.
CONCLUSIONS: The SAF file is an elastically compressible file that effectively removes dentin and can mechanically endure use under its recommended mode of operation with a minimal loss of efficacy. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307745     DOI: 10.1016/j.joen.2009.12.028

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  18 in total

1.  Apical debris extrusion associated with oval shaped canals: a comparative study of WaveOne vs Self-Adjusting File.

Authors:  Eleftherios Terry R Farmakis; G G Sotiropoulos; I Abràmovitz; M Solomonov
Journal:  Clin Oral Investig       Date:  2016-01-12       Impact factor: 3.573

2.  Incidence of microcracks in maxillary first premolars after instrumentation with three different mechanized file systems: a comparative ex vivo study.

Authors:  A Kfir; D Elkes; A Pawar; A Weissman; I Tsesis
Journal:  Clin Oral Investig       Date:  2016-03-30       Impact factor: 3.573

3.  The self-adjusting file instrumentation results in less debris extrusion apically when compared to WaveOne and ProTaper NEXT.

Authors:  Ajinkya M Pawar; Mansing G Pawar; Zvi Metzger; Sharad R Kokate
Journal:  J Conserv Dent       Date:  2015 Mar-Apr

4.  Self-adjusting file (SAF) separation in clinical use: A preliminary survey among experienced SAF users regarding prevalence and retrieval methods.

Authors:  Michael Solomonov; Joe Ben-Itzhak; Anda Kfir; Oscar von Stetten; Elena Lipatova; Eleftherios T Farmakis
Journal:  J Conserv Dent       Date:  2015 May-Jun

5.  Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments.

Authors:  Samia M Elsherief; Mohamed K Zayet; Ibrahim M Hamouda
Journal:  J Biomed Res       Date:  2013-06-25

Review 6.  The self-adjusting file (SAF) system: An evidence-based update.

Authors:  Zvi Metzger
Journal:  J Conserv Dent       Date:  2014-09

7.  Apical extrusion of debris by supplementary files used for retreatment: An ex vivo comparative study.

Authors:  Ajinkya M Pawar; Mansing Pawar; Zvi Metzger; Bhagyashree Thakur
Journal:  J Conserv Dent       Date:  2016 Mar-Apr

8.  The efficacy of the Self-Adjusting File versus WaveOne in removal of root filling residue that remains in oval canals after the use of ProTaper retreatment files: A cone-beam computed tomography study.

Authors:  Ajinkya M Pawar; Bhagyashree Thakur; Zvi Metzger; Anda Kfir; Mansing Pawar
Journal:  J Conserv Dent       Date:  2016 Jan-Feb

9.  Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study.

Authors:  Suparna Ganguly Saha; Neelam Vijaywargiya; Divya Saxena; Mainak Kanti Saha; Anuj Bharadwaj; Sandeep Dubey
Journal:  J Conserv Dent       Date:  2017 Sep-Oct

10.  Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: An ex-vivo cone-beam computed tomography analysis.

Authors:  Dipali Yogesh Shah; Swati Ishwara Wadekar; Ashwini Manish Dadpe; Ganesh Ranganath Jadhav; Lalit Jayant Choudhary; Dheeraj Deepak Kalra
Journal:  J Conserv Dent       Date:  2017 Mar-Apr
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.